Significant influence of scaler tip design on root substance loss resulting from ultrasonic scaling: a laserprofilometric in vitro study.
نویسندگان
چکیده
OBJECTIVES Ultrasonic scalers have become increasingly popular for subgingival debridement. The aim of the present study was to investigate the influence of different working tip designs (narrow versus wide) on root substance loss caused by either magnetostrictive or piezoelectric ultrasonic devices. METHODS In this in vitro study, a magnetostrictive ultrasonic system with either Slimline or TFI-10 inserts and a piezoelectric ultrasonic system with either Perioprobe or Type-A inserts were compared at different application forces. Loss of root dentin was determined by defect width, defect depth and defect volume resulting from standardized instrumentation using laser profilometry. RESULTS There were consistent and statistically significant differences between all groups. The mean observed dentin alterations for the magnetostrictive ultrasonic device operating a Slimline insert at a lateral force of 0.3 N were 254.4 microm, 6.3 microm and 22.5 microm3 and for the TFI-10 tip 759.0 microm, 23.5 microm and 160.2 microm3 for the parameters defect width, depth and volume, respectively. For the piezoelectric ultrasonic system operating a Perioprobe insert, the corresponding mean values were 352.0 microm/12.1 microm/56.4 microm3 and for the universal Type-A insert they were 402.4 microm/14.0 microm/133.4 microm3. With application forces of 0.7 N, root substance removal increased up to twofold. CONCLUSION The present investigation could demonstrate that the aggressiveness of magnetostrictive and piezoelectric ultrasonic devices to root substance was significantly influenced by the scaler tip designs, increasing for wider scaler tips as compared with narrow, probe-shaped inserts.
منابع مشابه
Root surface defect produced by hand instruments and ultrasonic scaler with different power settings: an in vitro study.
The aim of this study was to evaluate the root surface defect produced by hand curettes and ultrasonic tips with different power settings. Forty root surfaces were divided into 4 groups according the treatment: Gracey curettes, ultrasonic scaler at 10% power, ultrasonic scaler at 50% power and ultrasonic scaler at 100% power. Each specimen was instrumented with 15 strokes and the and divided in...
متن کاملComparative evaluation of roughness of titanium surfaces treated by different hygiene instruments
PURPOSE The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. METHODS Thirty-seven identical disks ...
متن کاملEffect of instrumentation using curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser on the morphology and adhesion of blood components on root surfaces: a SEM study.
This study used scanning electron microscopy (SEM) to evaluate the morphology and adhesion of blood components on root surfaces instrumented by curettes, piezoelectric ultrasonic scaler and Er,Cr:YSGG laser. One hundred samples from 25 teeth were divided into 5 groups: 1) Curettes; 2) Piezoelectric ultrasonic scaler; 3) Curettes plus piezoelectric ultrasonic scaler; 4) Er,Cr:YSGG laser; 5) Cure...
متن کاملEvaluation of the safety and efficiency of novel metallic implant scaler tips manufactured by the powder injection molding technique
BACKGROUND Although many studies have compared the properties of ultrasonic scaling instruments, it remains controversial as to which is most suitable for implant scaling. This study evaluated the safety and efficiency of novel metallic ultrasonic scaler tips made by the powder injection molding (PIM) technique on titanium surfaces. METHODS Mechanical instrumentation was carried out using fou...
متن کاملUltramorphology of the root surface subsequent to hand-ultrasonic simultaneous instrumentation during non-surgical periodontal treatments. An in vitro study
OBJECTIVE The purpose of this study was to investigate the ultramorphology of the root surfaces induced by mechanical instrumentation performed using conventional curettes or piezoelectric scalers when used single-handedly or with a combined technique. MATERIAL AND METHODS Thirty single-rooted teeth were selected and divided into 3 groups: Group A, instrumentation with curettes; Group B instr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical periodontology
دوره 31 11 شماره
صفحات -
تاریخ انتشار 2004