Automatic analysis of normal bone marrow blood cells using the XE-2100 automated hematology analyzer.
نویسندگان
چکیده
The bone marrow aspiration test conventionally has been performed by visual methods, using a light microscope, because automatic blood cell analyzers cannot adequately capture erythroblasts and immature granulocytes (IGs) (Tatsumi et al.: Osaka City Med J 1988;34:135-146; Tatsumi et al.: Am J Clin Pathol 1986;86:50-54). With the development of the XE-2100 automatic blood cell analyzer (Sysmex Corporation, Kobe, Japan) in 1999, the classification of erythroblasts and IGs by means of flow cytometry (Zini et al.: Infus Ther Transfus Med 2001;28:277-279; Briggs et al.: Sysmex J Int 1999;9:113-119) became possible. In the present study we classified cells in 65 bone marrow aspiration specimens by the microscopic method and with the XE2100, and compared the results. A good correlation was found in the nucleated red blood cell (NRBC), white blood cell (WBC), and total nucleated cell (TNC) counts; the myeloid/erythroid ratio (M/E ratio); neutrophils, lymphocytes, eosinophils, and IGs in the immature myeloid information (IMI) channel; and the total cell count. These items can all be analyzed in about 54 sec with the XE2100, which is faster than with the microscopic method. Therefore, analysis of bone marrow aspiration specimens with this apparatus appears to be very useful for clinical screening as well as laboratory testing.
منابع مشابه
Automation of bone marrow aspirate examination using the XE-2100 automated hematology analyzer.
BACKGROUND Attempts to analyze bone marrow aspirates have been reported with the use of several automated blood cell counters, but sufficient accuracy in examination is not acquired yet. Major problems have included difficulties in correctly differentiating various immature cells and interference by lipid in bone marrow aspirates. The goal of this study was to solve these problems to attain mor...
متن کاملPreliminary Data on the Feasibility of Bone Marrow Screening on the Sysmex XE-2100 Automated Hematology Analyzer
In the present study we investigated the potential of the Sysmex XE-2100 automated hematology analyzer as a screening device for bone marrow (BM) aspirates. We evaluated BM cellularity, white blood cell (WBC) differential count, immature granulocyte (IG) count, nucleated red blood cell (NRBC) count, granulocyte/erythroid (G/E) and myeloid/erythroid (M/E) ratio, and potential pathologyrelated sc...
متن کاملEvaluation of the Diagnostic Performance of theSysmex XT-2000i Automated Hematology Analyzerin the Detection of Immature Granulocyte
Immature Granulocytes (IG) are normally not present in peripheral blood. Their presence is an important indicator of enhanced bone marrow activation. The present study evaluated the diagnostic performance of the Sysmex XT-2000i automated hematology analyzer in the detection of myelocytes and/or metamyelocytes in patients affected by non-haematological disease, in comparison with manual microsco...
متن کاملOverview of Automated Hematology Analyzer XE-2100
The XE-2100 is a new automated hematology analyzer developed by Sysmex Corporation. With consideration of medical analyzer requirements for the 21st century, this unit was developed to satisfy the following concepts and to cope with diversified laboratory needs. 1) Electronic network communication 2) Presentation of high level value-added information 3) Contribution to test cost control 4) Purs...
متن کاملPerformance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer.
Recently, St. Anthony's Medical Center Laboratory (SAMC) in St. Louis, Missouri, installed a new automated hematology analyzer, the Sysmex XE-2100. The XE-2100 has an additional differential parameter, the immature granulocyte (IG) parameter. Prior to implementation, the IG parameter was evaluated by comparison to the manual immature granulocyte count. Immature granulocytes counted manually, as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical laboratory analysis
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2003