Changes in intraocular pressure and ocular pulse amplitude with accommodation.

نویسندگان

  • Scott A Read
  • Michael J Collins
  • Heidi Becker
  • Jeremy Cutting
  • Danielle Ross
  • Annyck K Savill
  • Beth Trevor
چکیده

AIMS To investigate the change that occurs in intraocular pressure (IOP) and ocular pulse amplitude (OPA) with accommodation in young adult myopes and emmetropes. METHODS Fifteen progressing myopic and 17 emmetropic young adult subjects had their IOP and OPA measured using the Pascal dynamic contour tonometer. Measurements were taken initially with accommodation relaxed, and then following 2 min of near fixation (accommodative demand 3 D). Baseline measurements of axial length and corneal thickness were also collected prior to the IOP measures. RESULTS IOP significantly decreased with accommodation in both the myopic and emmetropic subjects (mean change -1.8+/-1.1 mm Hg, p<0.0001). There was no significant difference (p>0.05) between myopes and emmetropes in terms of baseline IOP or the magnitude of change in IOP with accommodation. OPA also decreased significantly with accommodation (mean change for all subjects -0.5+/-0.5, p<0.0001). The myopic subjects (baseline OPA 2.0+/-0.7 mm Hg) exhibited a significantly lower baseline OPA (p=0.004) than the emmetropes (baseline OPA 3.2+/-1.3 mm Hg), and a significantly lower magnitude of change in OPA with accommodation. CONCLUSION IOP decreases significantly with accommodation, and changes similarly in progressing myopic and emmetropic subjects. However, differences found between progressing myopes and emmetropes in the mean OPA levels and the decrease in OPA associated with accommodation suggested some changes in IOP dynamics associated with myopia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ophthalmic pulse studies. I. Influence of intraocular pressure.

The relationship of the ophthalmic pulse amplitude to the intraocular pressure has been described in rabbits and dogs. The effect of a suction cup on the intraocular pressure has been investigated in rabbit eyes and human eyes. Sample pulse tracings have been obtained using a suction cup on rabbits and man. Two estimates were made of the volume changes associated with the ophthalmic pulse xoave...

متن کامل

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Evaluation of ocular accommodation, convergence and fusional vergence changes during Ramadan

Purpose: There are a few researches regarding the effects of Islamic fasting on visual system. The aim of this study was to investigate the effects of Ramadan fasting on the amplitude of accommodation (AA), near point of convergence (NPC), positive and negative fusional vergences (PFV and NFV, respectively) in visually healthy fasters. Methods: AA, NPC, PFV and NFV at far (6m) and near (40cm) w...

متن کامل

The ocular pulse and intraocular pressure as a screening test for carotid artery stenosis.

The ocular pulse and applanation tension were measured with a recording applanation tonometer in 38 patients suspected of having internal carotid artery stenosis. Abnormalities of the ocular pulse amplitude, intraocular pressure, or combinations of these two measurements were found in 23 (82%) of 28 patients who were subsequently found to have angiographic evidence of 50% or more stenosis of on...

متن کامل

The influence of sex difference in measurements with the Langham Ocular Blood Flow System.

PURPOSE To assess sex difference and parameters possibly accounting for such a difference in healthy subjects evaluated by means of the Langham Ocular Blood Flow (OBF) System. METHODS Pulse amplitude of intraocular pressure (IOP) and pulsatile ocular blood flow (POBF) as measured with the Langham OBF System were assessed in 86 healthy men and 69 healthy women. RESULTS Compared to men, women...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 94 3  شماره 

صفحات  -

تاریخ انتشار 2010