Investigation of biofilm formation on a charged intravenous catheter relative to that on a similar but uncharged catheter
نویسندگان
چکیده
Catheter-related blood stream infections increase morbidity, mortality, and costs. This study investigated whether Certofix(®) protect antimicrobial catheters carry a surface charge and whether this inhibits biofilm formation. The capacitance of the catheter surfaces was measured and, to determine if the catheters released ions, distilled water was passed through and current measured as a function of voltage. With probes touching the inner and outer surfaces, capacitance was not voltage-dependent, indicating surfaces were uncharged or carried a similar charge. When one probe penetrated the catheter wall, capacitance was weakly voltage-dependent, indicating the presence of a surface charge. Standard and charged catheters were also exposed to phosphate buffered saline as controls or 2×10(6) colony forming units/mL (in phosphate buffered saline) of six different microorganisms for 60 or 120 minutes. When the growth of detached bacteria was measured, biofilm formation was significantly reduced, (P<0.05), for charged catheters for all organisms.
منابع مشابه
The ability of uropathogenic Escherichia coli isolates in biofilm formation on urinary catheter and association with bcsA and draE genes
The product biofilm by E.coli strain can cause serious problem for human health. Catheter is considered to be s suitable place for colonization of microorganisms, so that in %5-10 of patients who used catheter for only one day and also in all patients who used it for over 28 days, this colonization of bacteria is observed on catheter. This study is come out in order to compare biofilm formation...
متن کاملPlasma can reduce Staphylococcus epidermidis biofilm formation on medical polymers
Medical polymers, such as urinary catheters are widely used biomaterials. One of the main problem for using the urinary catheters is biofilm formation on their surface, when they are used in a long time in the body. Virulence and pathogenicity of Staphylococcus epidermidis is often enhanced when growing as a biofilm. Many techniques have been presented to reduce the biofilm formation by surface...
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملThe Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کامل