Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA.
نویسندگان
چکیده
UNLABELLED The plasma sample method following a single injection of radioactive markers has been proved to be simple and accurate for the determination of glomerular filtration rate (GFR) in clinical practice. The aim of this study was to assess clinical accuracy of single-, two- and multi-sample methods. METHODS The study was performed on 50 patients with various degrees of renal dysfunction (29 males and 21 females; aged 27 to 90 years). As a reference the true GFR (GFRt) was determined by means of the two-compartment model curve fitting 10 plasma samples following a single-injection of 99mTc-DTPA. The GFRt was compared to the GFR estimated by the Christensen and Groth's single-sample (GFRcg), two-sample (GFR2s) and multi-sample (GFRm) between 75 and 300 min after the injection. The GFRs by two- and multi-sample methods were determined with the slope and intercept algorithm and its overestimation was corrected by Brochner-Mortensen's formula. RESULTS In 49 patients with GFR between 12 and 169 ml/min/1.73 m2, the standard deviation of difference (95% limits of agreement) between GFRt and GFRcg at 180 min was 6.513 ml/min/l73 m2 (-16.5 approximately 9.5 ml/min/1.73 m2), which was somewhat closer than 7.311 ml/min/1.73 m2 (-12.5 approximately 16.5 ml/min/1.73 m2) in GFR2s in slow clearance phase at 120 min and 240 min. However, the single-sample method tended to show some scattering in GFR below 30 and above 140 ml/min/ 1.73 m2. On the contrary, the 2-sample method tended to be scattered in GFR above 120 ml/min/ 1.73 m2. CONCLUSION In view of its accuracy and technical simplicity, the single-sample method is first choice in a routine practice. The two-sample method is essential of choice for a patient in whom the GFR is expected to be below 30 ml/min/1.73 mi2. These two methods may be chosen selectively in dependence on the preserved renal function which is expected at time of the test.
منابع مشابه
Determining an accurate method to estimate GFR in renal transplant recipients with stable serum creatinine levels
Introduction:Detecting renal allograft dysfunction early will allow timely diagnosis and treatment. There is no objective recommendation by national kidney societies for glomerular filtration rate (eGFR) estimation in post-transplant setting. 99mTc-DTPA Technetium-99m Diethylene triamine penta acetic acid) renogram can identify early renal dysfunction much before ser...
متن کاملDetermination of glomerular filtration rate using technetium-99m-DTPA with differing degrees of renal function.
UNLABELLED Glomerular filtration rate (GFR) is an important index of renal function. Twenty-four-hour creatinine clearance overestimates GFR in patients with poor renal function. Inulin and iothalamate clearances are accepted reference standards for determining GFR but are expensive and laborious. We have previously reported that GFRs obtained by measuring the disappearance of 99mTc-DTPA from u...
متن کاملComparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method.
BACKGROUND The gamma camera uptake method with Tc-99m-DTPA is simple and less time consuming for the determination of the glomerular filtration rate (GFR). However, its diagnostic accuracy is debated. Gates' method and predicted creatinine clearance method were compared with plasma clearance method with Tc-99m-DTPA for the measurement of GFR. MATERIALS AND METHODS Tc-99m-DTPA renography was p...
متن کاملRapid method for the measurement of differential renal function: validation.
The precise measurement of glomerular filtration rate (GFR) and renal plasma flow (ERPF) usually requires continuous intravenous administration of adequate substances, with multiple blood and urine analysis, and does not allow measurement of separate renal function. Schlegel et al. and Gates described isotopic methods for the measurement of global and unilateral GFR and ERPF based on the determ...
متن کاملMeasurement of glomerular filtration rate with Tc-99m DTPA [Persian]
Abstract is NOT available
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 16 1 شماره
صفحات -
تاریخ انتشار 2002