Instantaneous Active and Reactive Power and Current Strategies for Current harmonics cancellation in 3-ph 4wire SHAF With both PI and Fuzzy Controllers

نویسندگان

  • Suresh Mikkili
  • Anup Kumar Panda
چکیده

Control strategies for extracting the three-phase reference currents for shunt active power filters are compared, evaluating their performance under different source conditions with PI and Fuzzy Controllers in MATLAB/Simulink environment When the supply voltages are balanced and sinusoidal, the two control strategies are converge to the same compensation characteristics; However, the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The compensation capabilities are not equivalent, with p-q control strategy unable to yield an adequate solution when source voltages are not ideal. Extensive simulations are carried out with PI controller and also with Fuzzy controller for both p-q and id-iq control strategies under different main voltages. Extensive Simulations are carried out with PI as well as fuzzy controller for both p-q and id-iq control strategies by considering different voltage conditions and adequate results were presented. On owing id-iq method with fuzzy logic controller gives away an out-standing performance under any voltage conditions (balanced, un-balanced, balanced and non-sinusoidal).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

Comparison between Two Types of Current Control Techniques Applied to Shunt Active Power Filters and Development of a Novel Fuzzy Logic Controller to Improve SAPF Performance

In this paper two types of current control techniques, namely, direct and indirect current control techniques are employed to a three phase shunt active power filter for the compensation of the harmonics in the current caused by the non-linear loads. The difference between these two types of current control technique is in the number of current sensors used. In direct current control technique ...

متن کامل

PI, FUZZY and ANFIS Control of 3-Phase Shunt Active Power Filter

Abstract—this paper describes control of 3-phase shunt active filter by using PI, fuzzy and ANFIS controls to improve the power quality and reactive power compensation and harmonic current compensation due to nonlinear loads. The controller is capable of controlling the DC capacitor voltage capable of reference source current. Hysteresis control is used to control the current in PWM inverter. T...

متن کامل

Frequency Regulation of AUT Microgrid Using Modified Fuzzy PI Controller for Flywheel Energy Storage System

Usage of flywheel energy storage system (FESS) is a common method for frequency regulation due to its high power injection capacity and long life time. FESS is equipped by two back-to-back inverters including grid-side inverter and machine-side inverter. In conventional method, the machine-side inverter sets the active power and machine flux while grid-side inverter sets the reactive power and ...

متن کامل

Direct Power Control With NSTSM Algorithm for DFIG Using SVPWM Technique

The paper presents a super-twisting sliding mode (STSM) regulator with neural networks (NN) of direct power command (DPC) for controlling the active/reactive power of a doubly-fed induction generator (DFIG) using a two-level space vector pulse width modulation (2L-SVPWM). Traditional DPC strategy with proportional-integral (PI) controllers (DPC-PI) has significantly more active/reactive power r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011