Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors.
نویسندگان
چکیده
Analysis of detective quantum efficiency (DQE) is an important component of the investigation of imaging performance for flat-panel detectors (FPDs). Conventional descriptions of DQE are limited, however, in that they take no account of anatomical noise (i.e., image fluctuations caused by overlying anatomy), even though such noise can be the most significant limitation to detectability, often outweighing quantum or electronic noise. We incorporate anatomical noise in experimental and theoretical descriptions of the "generalized DQE" by including a spatial-frequency-dependent noise-power term, S(B), corresponding to background anatomical fluctuations. Cascaded systems analysis (CSA) of the generalized DQE reveals tradeoffs between anatomical noise and the factors that govern quantum noise. We extend such analysis to dual-energy (DE) imaging, in which the overlying anatomical structure is selectively removed in image reconstructions by combining projections acquired at low and high kVp. The effectiveness of DE imaging in removing anatomical noise is quantified by measurement of S(B) in an anthropomorphic phantom. Combining the generalized DQE with an idealized task function to yield the detectability index, we show that anatomical noise dramatically influences task-based performance, system design, and optimization. For the case of radiography, the analysis resolves a fundamental and illustrative quandary: The effect of kVp on imaging performance, which is poorly described by conventional DQE analysis but is clarified by consideration of the generalized DQE. For the case of DE imaging, extension of a generalized CSA methodology reveals a potentially powerful guide to system optimization through the optimal selection of the tissue cancellation parameter. Generalized task-based analysis for DE imaging shows an improvement in the detectability index by more than a factor of 2 compared to conventional radiography for idealized detection tasks.
منابع مشابه
Method for Dual High Energy X-ray Imaging with Flat Panel Detectors
Dual-energy X-ray imaging in the keV range is a well-known technique e.g. used in baggage scanning. It requires two measurements at different energies and/or detector efficiencies and allows displaying material properties as the effective atomic number and mass density. The method thus provides the information allowing identifying illicit materials such as explosives and contraband or high-Z ma...
متن کاملAn experimental comparison of detector performance for direct and indirect digital radiography systems.
Current flat-panel detectors either directly convert x-ray energy to electronic charge or use indirect conversion with an intermediate optical process. The purpose of this work was to compare direct and indirect detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on three flat-panel detectors,...
متن کاملPractical expressions describing detective quantum efficiency in flat-panel detectors
In radiology, image quality excellence is a balance between system performance and patient dose, hence x-ray systems must be designed to ensure the maximum image quality is obtained for the lowest consistent dose. The concept of detective quantum efficiency (DQE) is widely used to quantify, understand, measure, and predict the performance of x-ray detectors and imaging systems. Cascaded linear-...
متن کاملThree-Dimensional NEQ Transfer Characteristics of Volume CT using Direct and Indirect-Detection Flat-Panel Imagers
Foremost among the promising imaging performance characteristics of cone-beam CT using flat-panel imagers is the ability to form volumetric images with soft-tissue contrast visibility in combination with sub-millimeter 3-D spatial resolution. Each of these two essential characteristics is intimately related to the spatial-frequency-dependent signal and noise transfer characteristics of the imag...
متن کاملPerformance of Large Area Thin-Film CdTe Detector in Diagnostic X-Ray Imaging
Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic performance of the detector for a range of energies relevant to diagnostic imaging applications, such as fluoroscopy. The input x-ray spectra for a set of tube potentials ranging ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 32 5 شماره
صفحات -
تاریخ انتشار 2005