Model falsification diagnosis and sensor placement for leak detection in pressurized pipe networks

نویسندگان

  • James-A. Goulet
  • Sylvain Coutu
  • Ian F. C. Smith
چکیده

Pressurized pipe networks used for fresh-water distribution can take advantage of recent advances in sensing technologies and data-interpretation to evaluate their performance. In this paper, a leak-detection and a sensor placement methodology are proposed based on leak-scenario falsification. The approach includes modeling and measurement uncertainties during the leak detection process. The performance of the methodology proposed is tested on a full-scale water distribution network using simulated data. Findings indicate that when monitoring the flow velocity for 14 pipes over the entire network (295 pipes) leaks are circumscribed within a few potential locations. The case-study shows that a good detectability is expected for leaks of 50 L/min or more. A study of measurement configurations shows that smaller leak levels could also be detected if additional pipes are instrumented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Measurement Site Design in pipe networks using the Decision Table Method (DTM)

The accuracy of leak detection and calibration of pipe networks by means of the inverse transient analysis (ITA) is highly affected by the number and location of the measurement sites. This study introduces a conceptual decision-making model, the Decision Table Method (DTM), for the measurement site design of pipe networks with the aim of inverse transient analysis. Through the Decision Table M...

متن کامل

Leak Detection and Isolation in Pressurized Water Pipe Networks using Interval LPV Models

In this paper, a leak detection and isolation methodology in pressurized water pipe networks is proposed. The methodology is based on computing residuals which are obtained comparing measured pressures (heads) in selected points of the network and their estimated values by means of an interval Linear Parameter Varying (LPV) model. The structure of the LPV models is obtained from the nonlinear m...

متن کامل

INVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

متن کامل

Leak Detection, Isolation and Estimation in Pressurized Water Pipe Networks Using LPV Models and Zonotopes

In this paper, a leak detection, isolation and estimation methodology in pressurized water pipe networks is proposed. The methodology is based on computing residuals which are obtained comparing measured pressures (heads) in selected points of the network with their estimated values by means of a Linear Parameter Varying (LPV) model and zonotopes. The structure of the LPV model is obtained from...

متن کامل

Performance comparison of reduced models for leak detection in water distribution networks

This paper presents a methodology for comparing the performance of model-reduction strategies to be used with a diagnostic methodology for leak detection in water distribution networks. The goal is to find reduction strategies that are suitable for error-domain model falsification, a model based data interpretation methodology. Twelve reduction strategies are derived from five strategy categori...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Advanced Engineering Informatics

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2013