Detection of a fish bone in the cervical esophagus using point-of-care ultrasound

نویسنده

  • T Kameda
چکیده

Case presentation We herein report the case of the accidental ingestion of a fish bone which was detected in the cervical esophagus by means of point-of-care ultrasound. A-70-year-old woman presented at the emergency department of our hospital with odynophagia in the neck after eating a slice of grunt (a type of fish) simmered in broth. Prior to this presentation she had already undergone direct laryngoscopy without any fish bone being identified at an otorhinolaryngology clinic. Point-of-care ultrasound was thereafter performed. As a result, a linear and hyperechoic structure was thus identified in the cervical esophagus. The structure did not seem to penetrate the wall of the esophagus. Computed tomography confirmed the same finding without any penetration. An endoscopic examination revealed a fish bone stuck in the cervical esophagus. The bone measured 17 mm in length, and was safely removed under endoscopic guidance. Subsequently the patient demonstrated a good recovery without any complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Esophagotomy in a domestic fowl: a rare case report

Background: Foreign body in esophagus in birds is rarely reported in literature. Most common site of foreign body in birds is proventriculus and ventriculus. The purpose of this study is to discuss the diagnosis of a large sharp foreign body in the distal third of the neck by plain radiography and its retrieval through esophagotomy and subsequent survival of the fowl. C...

متن کامل

مقایسه نتایج سونوگرافی با گرافی ساده گردن در شناسایی جسم خارجی مری سرویکال

Background: Detection of retained foreign bodies remains a significant problem in the emergency department. Foreign bodies can go undetected causing infectious complications ultrasonography is too inaccessible and expensive. The purpose of this study is comparison of ultrasonography with radiography for the detection of cervical esophageal foreign bodiesMethods: This cross-sectional study evalu...

متن کامل

Determination of Relationships between the Ultrasound Velocity and the Physical Properties of Bovine Cortical Bone Femur

Accurate measurements of physical characteristics of bone are essential for diagnosis, assessment of change following treatment, and therefore, indirectly, for evaluation of new forms of therapy. This is particularly true of osteoporosis and aging skeleton, in which fractures occur easily. Methods: In this study an ultrasonic system was set-up and calibrated on Plexiglas tubes of variable thick...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

پایداری فوری قدام مهره های گردن با متیل متاکریلات به جای پیچ و صفحه کاسپار

Background and purpose: The common method of stabilization in noncancerous lesions of anterior cervical vertebrae is the use of interbody bone graft and instulation of caspar plate and screws which is followed by several complications, breaking or loosing of screw, damage to esophagus and improper fusion of bone graft, as a result, damage to spinal cord during fixing the screw and also expous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015