Effects of phase aberration on high frame rate imaging.

نویسندگان

  • J Y Lu
  • S He
چکیده

A high frame-rate (HFR) imaging method (about 3750 frames/s for imaging of biological soft tissues at a depth of 200 mm) has been developed recently with limited diffraction beams. This method uses the fast Fourier transform (FFT) and inverse fast Fourier transform (IFFT) to construct images, and can be implemented with simple and inexpensive hardware, compared to the conventional delay-and-sum method where a digital beam former is usually used. In this paper, phase aberration effects are studied for both the high frame rate and the conventional methods by adding random phase shifts to echo signals obtained from an experiment. In the study, two broadband linear arrays were used to construct images of an ATS 539 tissue-equivalent phantom that has a frequency-dependent attenuation of about 0.5 dB/MHz/cm. The first array has 48 elements, a central frequency of 2.25 MHz, an aperture of 18.288 mm, and a width of 12.192 mm in elevation. The second has 64 elements, a central frequency of 2.5 MHz, and a dimension of 38.4 mm x 10 mm. The-6dB pulse-echo bandwidth of both arrays is about 40% of their center frequencies. Radiofrequency (RF) signals were digitized at 20 mega samples/s at a 12-bit resolution to construct images. Results show that phase aberration has about the same effect on both methods in terms of image resolution and contrast, although the high frame-rate method can be implemented with a simpler system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative assessment of effects of phase aberration and noise on high-frame-rate imaging.

The goal of this paper is to quantitatively study effects of phase aberration and noise on high-frame-rate (HFR) imaging using a set of traditional and new parameters. These parameters include the traditional -6-dB lateral resolution, and new parameters called the energy ratio (ER) and the sidelobe ratio (SR). ER is the ratio between the total energy of sidelobe and the total energy of mainlobe...

متن کامل

Effects of optimized photorefractive keratectomy (PRK) operation on the asphericity and high-order aberration changes

Background: Optimized is a common and important method in which aberrations are created by the device and the surgeon, but high-grade aberrations are out of the surgeon's control and are induced by the device in the patient. The aim of this study was the evaluation of out-of-control high-order aberration changes before and after PRK surgery and these impact on vision outcome. Materials and meth...

متن کامل

CYTOGENETIC EFFECTS OF MAGNETIC AND RADIOFREQUENCY FIEL DS OF NMRI SYSTEMS ON THE FREQUENCY OF CHROMOSOMAL ABERRATIONS INHUMAN LYMPHOCYTES IN THE PRESENCE OR ABSENCE OF CYTOSINE ARABINOSIDE

Application of nuclear magnetic resonance imaging (NMRI) as a non-invasive and accurate imaging procedure has been widely used in recent years. Meanwhile, the biological effects of magnetic fields of several tesla (T) and high energy radiofrequency (RF) is not fully known yet. Because of controversy over this issue, the present research has been carried out in order to verify the effects of...

متن کامل

Radiosensitizing effects of melatonin on radiation induced chromosomal aberration in G2-lymphocytes of breast cancer patients

Background: Radiotherapy is regarded as a standard treatment modality in breast cancer (BC). Radiation causes cellular damage both in cancer and normal cells by inducing DNA-damage and chromosomal aberrations (CA). Different agents were used for ameliorating effects of radiation, mainly antioxidants such as melatonin. Melatonin shows oncostatic properties on human BC. The aim of this study was ...

متن کامل

Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.

The design and construction of a double-hexapole aberration corrector has made it possible to build the prototype of a spherical-aberration corrected transmission electron microscope dedicated to high-resolution imaging on the atomic scale. The corrected instrument, a Philips CM200 FEG ST, has an information limit of better than 0.13 nm, and the spherical aberration can be varied within wide li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2000