High-resolution broadband N2 coherent anti-Stokes Raman spectroscopy: comparison of measurements for conventional and modeless broadband dye lasers.

نویسندگان

  • Joel P Kuehner
  • Mark A Woodmansee
  • Robert P Lucht
  • J Craig Dutton
چکیده

We have performed high-resolution N2 coherent anti-Stokes Raman spectroscopy (CARS) measurements using a modeless dye laser (MDL) as the Stokes beam source to determine the effects of a reduction in mode noise on the accuracy and precision of the method. These results are compared with previous research that employed a conventional broadband dye laser (CBDL) as the Stokes beam source. A new spectral-fitting procedure was developed to avoid starting-point bias in the least-squares fitting results, which possibly had altered the previous measurements. Single-shot measurements of pressure were performed in a static-pressure vessel over the range of 0.1-4.0 atm to examine the pressure sensitivity of the technique. The precision of these measurements is a measure of the baseline noise level of the system, which sets the detection limit for flow-field pressure fluctuations. Centerline measurements of pressure and temperature in an underexpanded jet (Mj = 1.85) were also used to determine the performance of the technique in a compressible flow field. Our study represents the first known application, to our knowledge, of a MDL CARS system in a low-temperature, low-pressure supersonic environment. Improvements in accuracy for mean single-shot measurements and increased precision were found for pressure vessel conditions above 1.0 atm. For subatmospheric pressure vessel conditions (0.1-1.0 atm) and the underexpanded jet measurements, there was a decrease in accuracy and precision compared with the CBDL results. A comparison with the CBDL study is included, along with a discussion of the MDL system behavior.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Broadband coherent anti-Stokes Raman scattering spectroscopy of nitrogen using a picosecond modeless dye laser.

Broadband picosecond coherent anti-Stokes Raman scattering (CARS) spectroscopy of nitrogen is demonstrated using 145-ps pump and probe beams and a 115-ps Stokes beam with a spectral bandwidth of 5 nm. This is, to our knowledge, the first demonstration of broadband CARS using subnanosecond lasers. The short temporal envelope of the laser pulses and the broadband spectral nature of the Stokes bea...

متن کامل

Thermometry for turbulent flames by coherent anti-Stokes Raman spectroscopy with simultaneous referencing to the modeless excitation profile.

An optimal system for temperature measurements by coherent anti-Stokes Raman spectroscopy (CARS) in turbulent flames and flows is presented. In addition to a single-mode pump laser and a modeless dye laser, an echelle spectrometer with a cross disperser is used. This system permits simultaneous measurement of the N2 CARS spectrum and the broadband dye laser profile. A procedure is developed to ...

متن کامل

Broadband coherent anti-Stokes Raman spectroscopy with a modeless dye laser.

We develop a modeless dye laser for broadband coherent anti-Stokes Raman spectroscopy (CARS) and investigate the operational characteristics of the modeless laser. The energy efficiency of the modeless laser is 6%, and the beam divergence is 0.65 mrad. We construct a compact movable CARS system with the modeless laser and a graphite tube furnace to assess the accuracy of the CARS temperature. I...

متن کامل

Prolonged-excitation coherent Raman spectroscopy with spectral resolution beyond the transition linewidth using two tunable picosecond dye lasers

Received June 11, 1984; accepted September 20, 1984 A time-resolved coherent anti-Stokes Raman technique is demonstrated that yields a spectral resolution beyond the linewidth obtained in spontaneous Raman spectroscopy. Two picosecond dye lasers, independently tunable with low timing jitter, are used. The coherent material excitation is generated by long pump pulses and monitored by short delay...

متن کامل

Noise characteristics of single shot broadband Raman-resonant CARS with single- and multimode lasers: erratum.

A simple model is presented as an aid in understanding, first, the relative noise performance and, second, the noise reduction achievable by referencing, in different experimental approaches to single shot broadband coherent anti-Stokes Raman scattering (CARS). Qualitative agreement is obtained with previous experimental investigations of CARS noise. The broadband dye laser radiation is describ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 42 33  شماره 

صفحات  -

تاریخ انتشار 2003