Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear
نویسندگان
چکیده
Background Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV 102). Results The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.
منابع مشابه
Individual fit testing of hearing protection devices.
While hearing protection devices (HPD) have been the last and often only line of defense against noise-induced hearing loss in the workplace, their performance has been suspect. Laboratory evaluations have not proven to predict the actual performance of HPD in the field. Individual fit testing of HPD will allow the determination of HPD performance on individual workers, and this will improve th...
متن کاملارزیابی عملکرد آکوستیکی مانکن سر جهت استفاده در آزمون های تعیین قدرت کاهندگی صدای وسایل حفاظت شنوایی
Introduction:One of the recommended methods for evaluation effectiveness of hearing protection is use the acoustic fixture accordance with standard ISO 4869-3. The aim of this study was evaluate the acoustic performance of fixture for using in noise reduction rate tests of hearing protection devices in the laboratory. Methods: In this cross-sectional study , noise reduction rates o...
متن کاملارزیابی میزان کاهندگی صدای گوشی های ایرماف رایج برمبنای روش میدانی میکروفن داخل گوش در محیط های کاری
Background and aims Nominal noise reduction rating of the earmuff manufacturers can be different compared with the actual noise attenuation rating. The current study aimed to determine the actual noise reduction rate of current hearing protection devices in the real workplaces using a field microphone in real ear method (FMIRE). Methods: In this cross-sectional study, five common earmuffs we...
متن کاملبررسی میزان کاهندگی صدای وسایل حفاظت شنوایی برمبنای روش میکروفن داخل گوش MIRE در شرایط آزمایشگاهی
Introduction: Nominal noise reduction rate of the earmuff manufacturers can be different compared with the actual attenuation rate. The present study aimed to determine the actual noise reduction rate of common hearing protection devices using microphone in real ear method. Materials and Methods: In this study, five brands of common earmuffs used in Iranian industries were investigated on 30...
متن کاملSession 1aNS: Advanced Hearing Protection and Methods of Measurement I 1aNS4. Comparison of subjective and objective methods for the measurements of hearing protector devices attenuation and occlusion effect
With the increase popularity of individual fit testing and miniaturization of electronic components, the Field-Microphone-In-Real-Ear approach (F-MIRE) is becoming more appealing and well suited for estimating hearing protection devices (HPD) attenuation both in laboratory and in "real world" occupational conditions. The approach utilizes two miniature microphones to simultaneously measure the ...