Inter-electrode spacing of surface EMG sensors: reduction of crosstalk contamination during voluntary contractions.
نویسندگان
چکیده
We investigated the influence of inter-electrode spacing on the degree of crosstalk contamination in surface electromyographic (sEMG) signals in the tibialis anterior (target muscle), generated by the triceps surae (crosstalk muscle), using bar and disk electrode arrays. The degree of crosstalk contamination was assessed for voluntary constant-force isometric contractions and for dynamic contractions during walking. Single-differential signals were acquired with inter-electrode spacing ranging from 5 mm to 40 mm. Additionally, double differential signals were acquired at 10 mm spacing using the bar electrode array. Crosstalk contamination at the target muscle was expressed as the ratio of the detected crosstalk signal to that of the target muscle signal. The crosstalk contamination ratio approached a mean of 50% for the 40 mm spacing for triceps surae muscle contractions at 80% MVC and tibialis anterior muscle contractions at 10% MVC. For single differential recordings, the minimum crosstalk contamination was obtained from the 10 mm spacing. The results showed no significant differences between the bar and disk electrode arrays. During walking, the crosstalk contamination on the tibialis anterior muscle reached levels of 23% for a commonly used 22 mm spacing single-differential disk sensor, 17% for a 10 mm spacing single-differential bar sensor, and 8% for a 10 mm double-differential bar sensor. For both studies the effect of electrode spacing on crosstalk contamination was statistically significant. Crosstalk contamination and inter-electrode spacing should therefore be a serious concern in gait studies when the sEMG signal is collected with single differential sensors. The contamination can distort the target muscle signal and mislead the interpretation of its activation timing and force magnitude.
منابع مشابه
Crosstalk in surface electromyography of the proximal forearm during gripping tasks.
Electromyographic (EMG) crosstalk was systematically analyzed to evaluate the magnitude of common signal present between electrode pairs around the forearm. Surface EMG was recorded and analyzed from seven electrode pairs placed circumferentially around the proximal forearm in six healthy individuals. The cross-correlation function was used to determine the amount of common signal, which was fo...
متن کاملAdvanced Signal Processing Techniques Applied to Cross-talk Reduction in Forearm S-emg
In spite of the great advances in the mechanical and electronic components of prosthetic hands, they still lack the high number of degrees of freedom present in the real human hand. That is due, not to technical deficiencies, but to the much reduced amount of independent control signals available when using surface electromyography (s-EMG) from the forearm stump or other artificial sensors. Cro...
متن کاملA comparison of surface and fine wire EMG recordings of gluteus medius during selected maximum isometric voluntary contractions of the hip.
Electromyographic (EMG) studies into gluteus medius (GMed) typically involve surface EMG electrodes. Previous comparisons of surface and fine wire electrode recordings in other muscles during high load isometric tasks suggest that recordings between electrodes are comparable when the muscle is contracting at a high intensity, however, surface electrodes record additional activity when the muscl...
متن کاملSpatial variability of muscle activity during human walking: the effects of different EMG normalization approaches.
Human leg muscles are often activated inhomogeneously, e.g. in standing. This may also occur in complex tasks like walking. Thus, bipolar surface electromyography (sEMG) may not accurately represent whole muscle activity. This study used 64-electrode high-density sEMG (HD-sEMG) to examine spatial variability of lateral gastrocnemius (LG) muscle activity during the stance phase of walking, maxim...
متن کاملEffects of lung volume on diaphragm EMG signal strength during voluntary contractions.
The use of esophageal recordings of the diaphragm electromyogram (EMG) signal strength to evaluate diaphragm activation during voluntary contractions in humans has recently been criticized because of a possible artifact created by changes in lung volume. Therefore, the first aim of this study was to evaluate whether there is an artifactual influence of lung volume on the strength of the diaphra...