Comparison of Two Restoration Techniques in the Context of 3D Medical Imaging
نویسندگان
چکیده
In this paper, we compare two restoration techniques applied to 3D angiographies and to femoral CT scans. The rst technique uses a Partial Derivative Equation and the second one is based on an extension of adaptive Wiener lters. We rst present each method. Then, we discuss and compare the estimation of the local orientations in 3D images obtained either by the smoothed gradient and the principal curvature directions or by the eigenvectors of the structure tensor. A good estimation of the orientations is essential because it directs the restoration process. Finally, we compare the restored images on both synthetic and real images for the two studied applications.
منابع مشابه
Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy
Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (F...
متن کاملComparison Between Three-Dimensional Diffusion-Weighted PSIF Technique and Routine Imaging Sequences in Evaluation of Peripheral Nerves in Healthy People
Introduction: The present study aims to evaluate the Three-Dimensional Diffusion-Weighted reversed fast imaging with steady state free precession (3D DW-PSIF) sequence with respect to imaging of the peripheral nerves; the tibial, medial, and lateral plantar nerves in the lower extremity, ulnar and median nerve in the upper extremity, sciatic nerve, brachial plexus, and lumbosacral plexus, and a...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملVulvar Cancer: Dosimetric Comparison of Advanced 3D Conformal Radiation Therapy Technique with Anteroposterior and Posteroanterior Irradiation Techniques
Introduction: The commonly used technique of radiation therapy for vulvar cancer consists of anteroposterior (AP) and posteroanterior (PA) fields. This is the first study that reports the dosimetric comparison between the AP-PA techniques and the new 3D advanced conformal technique (3D-ACT) based on the multiplicity of treatment fields in patients with squamous cell ca...
متن کاملThe Comparison between Two Different Digital Panoramic Radiography Techniques in the Detection of Proximal Caries
Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a den...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001