Quality Indicators for Gi Endoscopic Procedures

نویسندگان

  • Douglas K. Rex
  • Douglas G. Adler
  • Mandeep S. Sawhney
  • Sachin Wani
  • David S. Weinberg
چکیده

Colonoscopy is widely used for the diagnosis and treatment of colon disorders. Properly performed, colonoscopy is generally safe, accurate, and well-tolerated. Visualization of the mucosa of the entire large intestine and distal terminal ileum usually is possible during colonoscopy. Polyps can be removed during colonoscopy, thereby reducing the risk of colon cancer. Colono scopy is the preferred method to evaluate the colon in most adult patients with large-bowel symptoms, iron defi ciency anemia, abnormal results on radiographic studies of the colon, positive results on colorectal cancer (CRC) screening tests, postpolypectomy and post-cancer resection surveillance, and diagnosis and surveillance in infl ammatory bowel disease. In addition, colono scopy is the most commonly used CRC screening test in the United States ( 1 ). Based on 2010 data, over 3.3 million outpatient colonoscopies are performed annually in the United States, with screening and polyp surveillance accounting for half of indications ( 2 ). Optimal eff ectiveness of colonoscopy depends on patient acceptance of the procedure, which depends mostly on acceptance of the bowel preparation ( 3 ). Preparation quality aff ects the completeness of examination, procedure duration, and the need to cancel or repeat procedures at earlier dates than would otherwise be needed ( 4,5 ). Ineff ective preparation is a major contributor to costs ( 6 ). Meticulous inspection ( 7,8 ) and longer withdrawal times ( 9–14 ) are associated with higher adenoma detection rates (ADR). A high ADR is essential to rendering recommended intervals ( 15 ) between screening and surveillance examinations safe ( 16,17 ). Optimal technique is needed to ensure a high probability of detecting dysplasia when present in infl ammatory bowel disease ( 17–21 ). Finally, technical expertise and experience will help prevent adverse events that might off set the benefi ts of removing neoplastic lesions ( 22 ). Recent studies report that colonoscopy is less eff ective in preventing proximal colon cancer and cancer deaths (ie, colon cancer proximal to the splenic fl exure) compared with distal cancer (ie, colon cancer at or distal to the splenic fl exure) ( 23–28 ). Decreased protection against right-sided CRC is likely due to multiple factors. Th ese include missed adenomas or incompletely resected adenomas; suboptimal bowel preparation; precancerous lesions that are endoscopically subtle or diffi cult to remove, such as sessile serrated polyps and fl at and/or depressed adenomas, and diff erences in tumorigenesis between right-sided and left -sided cancers. Improving prevention of right-sided colon cancer is a major goal of colonoscopy quality programs. Five studies have established that gastroenterologists are more eff ective than surgeons or primary care physicians at preventing CRC by colonoscopy ( 27,29–32 ). Th is most likely refl ects higher rates of complete examinations (ie, cecal intubation) ( 30 ) and higher rates of adenoma detection among gastroenterologists ( 33,34 ). All endoscopists performing colonoscopy should measure the quality of their colonoscopy. Institutions where endoscopists from multiple specialties are practicing should reasonably expect all endoscopists to participate in the program and achieve recommended quality benchmarks. Th e quality of health care can be measured by comparing the performance of an individual or a group of individuals with an ideal or benchmark ( 35 ). Th e particular parameter that is being used for comparison is termed a quality indicator. A quality indicator oft en is reported as a ratio between the incidence of correct performance and the opportunity for correct performance ( 4 ) or as the proportion of interventions that achieve a predefi ned goal ( 35 ). Quality indicators can be divided into 3 categories: (1) structural measures—these assess characteristics of the entire health care environment (eg, participation by a physician or other clinician in systematic clinical database registry that includes consensus endorsed quality measures), (2) process measures—these assess performance during the delivery of care (eg, ADR and adequate biopsy sampling during colonoscopy for chronic ulcerative colitis), (3) outcome measures—these assess the results of the care that was provided (eg, the prevention of cancer by colonoscopy and reduction in the incidence of colonoscopic perforation). Quality Indicators for Colonoscopy

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Upper Endoscopy in International Digestive Endoscopy Network 2012: Towards Upper End of Quality

Upper gastrointestinal (GI) endoscopy is the most basic part of endoscopy field. Although old and basic procedures are still in use, a line of innovative techniques and devices are being introduced to allow much complex and difficult procedures in endoscopy unit. High quality upper endoscopic procedures can replace or obviate surgical treatment. Selected reviews dealing with non-variceal upper ...

متن کامل

Education and Training Guidelines for the Board of the Korean Society of Gastrointestinal Endoscopy

The Korean Society of Gastrointestinal Endoscopy (KSGE) developed a gastrointestinal (GI) endoscopy board in 1995 and related regulations. Although the KSGE has acquired many specialists since then, the education and training aims and guidelines were insufficient. During GI fellowship training, obtaining sufficient exposure to some types of endoscopic procedures is difficult. Fellows should acq...

متن کامل

How to Improve the Quality of Screening Endoscopy in Korea: National Endoscopy Quality Improvement Program

In Korea, gastric cancer screening, either esophagogastroduodenoscopy or upper gastrointestinal series (UGIS), is performed biennially for adults aged 40 years or older. Screening endoscopy has been shown to be associated with localized cancer detection and better than UGIS. However, the diagnostic sensitivity of detecting cancer is not satisfactory. The National Endoscopy Quality Improvement (...

متن کامل

Evaluation of quality and patient satisfaction during endoscopic procedure: a cross sectional study from south Asian country.

OBJECTIVE To assess the quality of gastrointestinal (GI) endoscopic procedures and patient satisfaction in endoscopy suite of South Asian country. METHODS Patients coming to the endoscopic suite of Aga Khan University Hospital (AKUH) were interviewed and assessed in this cross-sectional study. Quality of GI endoscopic procedures was evaluated using assessment tools as suggested by The America...

متن کامل

Effect of general anesthesia during GI endoscopic procedures on patient satisfaction

AIM To compare the conventional GI endoscopy and using general anesthesia during the procedure regarding the satisfaction and acceptance among Iranian patients. BACKGROUND Ability to measure and assess the patients' satisfaction with colonoscopy and upper endoscopy will improve the quality of health care provided by gastroenterologists and thus resulting in better acceptability of endoscopy. ...

متن کامل

Endoscopists attitudes on the publication of "quality" data for endoscopic procedures: a cross-sectional survey

BACKGROUND Whilst the public now have access to mortality & morbidity data for cardiothoracic surgeons, such "quality" data for endoscopy are not generally available. We studied endoscopists' attitudes to and the practicality of this data being published. METHODS We sent a questionnaire to all consultant gastrointestinal (GI) surgeons, physicians and medical GI specialist registrars in the No...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014