Effect of Varying Hemodynamic and Vascular Conditions on Fractional Flow Reserve: An In Vitro Study

نویسندگان

  • Kranthi K. Kolli
  • James K. Min
  • Seongmin Ha
  • Hilary Soohoo
  • Guanglei Xiong
چکیده

BACKGROUND The aim of this study was to investigate the impact of varying hemodynamic conditions on fractional flow reserve (ratio of pressure distal [Pd] and proximal [Pa] to stenosis under hyperemia) in an in vitro setting. Failure to achieve maximal hyperemia and the choice of hyperemic agents may have differential effects on coronary hemodynamics and, consequently, on the determination of fractional flow reserve. METHODS AND RESULTS An in vitro flow system was developed to experimentally model the physiological coronary circulation as flow-dependent stenosis resistance in series with variable downstream resistance. Five idealized models with 30% to 70% diameter stenosis severity were fabricated using VeroClear rigid material in an Objet260 Connex printer. Mean aortic pressure was maintained at 7 levels (60-140 mm Hg) from hypotension to hypertension using a needle valve that mimicked adjustable microcirculatory resistance. A range of physiological flow rates was applied by a steady flow pump and titrated by a flow sensor. The pressure drop and the pressure ratio (Pd/Pa) were assessed for the 7 levels of aortic pressure and differing flow rates. The in vitro experimental data were coupled with pressure-flow relationships from clinical data for populations with and without myocardial infarction, respectively, to evaluate fractional flow reserve. The curve for pressure ratio and flow rate demonstrated a quadratic relationship with a decreasing slope. The absolute decrease in fractional flow reserve in the group without myocardial infarction (with myocardial infarction) was on the order of 0.03 (0.02), 0.05 (0.02), 0.07 (0.05), 0.17 (0.13) and 0.20 (0.24), respectively, for 30%, 40%, 50%, 60%, and 70% diameter stenosis, for an increase in aortic pressure from 60 to 140 mm Hg. CONCLUSIONS The fractional flow reserve value, an index of physiological stenosis significance, was observed to decrease with increasing aortic pressure for a given stenosis in this idealized in vitro experiment for vascular groups with and without myocardial infarction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical modeling of the flow in stenosed coronary artery. The relationship between main hemodynamic parameters

The severity of coronary arterial stenosis is usually measured by either simple geometrical parameters, such as percent diameter stenosis, or hemodynamically based parameters, such as the fractional flow reserve (FFR) or coronary flow reserve (CFR). The present study aimed to establish a relationship between actual hemodynamic conditions and the parameters that define stenosis severity in the c...

متن کامل

Comparative analysis of the effects of monetary and government financial expenditures shocks in the context of fractional and full reserve banking in Iran: DSGE approach

The present study aims to investigate the effects of monetary and financial shocks on macroeconomic variables in fractional and full reserve banking conditions. To this end, two stochastic dynamic general equilibrium models have been designed in terms of the realities of Iran's economy and then the effects of shocks have been studied. After determining the input values ​​of the model and estima...

متن کامل

Influence of hemodynamic conditions on fractional flow reserve: parametric analysis of underlying model.

Pressure-based fractional flow reserve (FFR) is used clinically to evaluate the functional severity of a coronary stenosis, by predicting relative maximal coronary flow (Q(s)/Q(n)). It is considered to be independent of hemodynamic conditions, which seems unlikely because stenosis resistance is flow dependent. Using a resistive model of an epicardial stenosis (0-80% diameter reduction) in serie...

متن کامل

Evaluation of Cardiac Function in Patients with Brain Death using Advanced Hemodynamic Monitoring

Background: Studies on hemodynamic changes in brain death are in vitro and in animal studies. And very few studies have been done on the hemodynamic changes of brain death. The aim of this study was to use advanced hemodynamic monitoring with echocardiography for evaluation of donated heart and to evaluate the moment by moment brain death patients with advanced hemodynamic monitoring tools and ...

متن کامل

Hemodynamic response to intravenous adenosine and its effect on fractional flow reserve assessment: results of the Adenosine for the Functional Evaluation of Coronary Stenosis Severity (AFFECTS) study.

BACKGROUND We studied the hemodynamic response to intravenous adenosine on calculation of fractional flow reserve (FFR). Intravenous adenosine is widely used to achieve conditions of stable hyperemia for measurement of FFR. However, intravenous adenosine affects both systemic and coronary vascular beds differentially. METHODS AND RESULTS A total of 283 patients (310 coronary stenoses) underwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016