In order to overcome existing complicated and costly simultaneous measurement system, an inexpensive and simple measurement system was suggested to measure the temperature field and velocity field at high temperature. The manganese-activated magnesium fluorogermanate (Mg4FGe6:Mn, MFG) which is one of thermographic phosphor with luminescence characteristic of excitation at 385 nm wavelength and emission 660 nm wavelength light was used as a tracer particle for PIV. Instead of costly Nd:YAG laser, Light Emitting Diode (LED) which is relatively inexpensive and alterable in terms of wavelength and only one high speed camera with CMOS sensor were used for the simultaneous measurement system. To validate the constructed simultaneous measurement system, dispersion of the confined oil jet with high temperature was investigated. The instantaneous temperature and velocity field were obtained when 200 oC of silicon oil was injected into the 25 oC of the silicon oil chamber. For the temperature field analysis, the decay – slope method was used, and the velocity field was obtained by two-frame cross correlation algorithm. The instantaneous temperature and velocity field were obtained successfully with 0.1 second time interval. It is investigated that the velocity of injected silicon oil was rapidly decreased because of the change of viscosity of silicon oil over temperature. And the injected high temperature silicon oil was cooled by surrounding low temperature silicon oil. Therefore, the velocity of oil jet was decreased rapidly and was dispersed widely. The temperature gradient is also related to oil jet dispersion. The temperature difference before and after of a dispersion point appears significantly, since the temperature of silicon oil difference between the spread widely area and non-spread area. The temperature filed and velocity filed were obtained successfully by simple simultaneous measurement system using thermographic phosphor tracer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermographic laser Doppler velocimetry.

We propose a point measurement technique for simultaneous gas temperature and velocity measurement based on thermographic phosphor particles dispersed in the fluid. The flow velocity is determined from the frequency of light scattered by BaMgAl10O17:Eu2+ phosphor particles traversing the fringes like in conventional laser Doppler velocimetry. Flow temperatures are derived using a two-color rati...

متن کامل

EFFECT OF NOZZLE DIAMETER AND ATOMIZING AIR PRESSURE ON CHARACTERISTICS OF IN-FLIGHT PARTICLES IN WIRE ARC SPRAYING

In wire arc spraying, the atomizing air pressure and applied nozzle system are important factors influencing particles characteristics and coating quality. The aim of this paper is to study how the characteristics of particles such as size, velocity and temperature are influenced by the operating conditions in wire arc spray. For that, three types of wires are tested: solid wire of stainless st...

متن کامل

Laser-Induced Phosphorescence in Combustion Diagnostics: Calibration at Extremely High Temperatures

This paper describes essential results for thermographic phosphorescence applications in laser diagnostics at extremely high temperatures for reacting and non-reacting flows. Promising results have been attained although these applications perform poorly in hostile environments. An experiment was conducted to investigate the viability of non-contact temperature measurements based on thermograph...

متن کامل

Transient measurements using thermographic phosphors.

The decay of thermographic phosphors has been used to measure temperature in a wide variety of applications. Because measurements of a single temperature are obtained from intensity decay in time, the use of phosphors is predicated on the fact that the temperature does not change during the decay. This may not be valid in some engineering applications. A new model for phosphor data reduction de...

متن کامل

Simulation of a Helium Atmospheric Plasma Jet Using Fluid Equations

In this study, a cold atmospheric He plasma jet is investigated. The jet is of dielectric barrier discharge type, consisting of a dielectric tube with two metal ring electrodes. The continuity, momentum and energy conservation equations as well as the Poisson equation for obtaining the potential and the electric field, accompanied with the ideal gas laws, are used for the simulation. The result...