State of the art for measurement of urine albumin: comparison of routine measurement procedures to isotope dilution tandem mass spectrometry.
نویسندگان
چکیده
BACKGROUND Urine albumin is the primary biomarker for detection and monitoring of kidney damage. Because fixed decision criteria are used to identify patients with increased values, we investigated if commonly used routine measurement procedures gave comparable results. METHODS Results from 17 commercially available urine albumin measurement procedures were investigated vs an isotope dilution mass spectrometry (IDMS) procedure. Nonfrozen aliquots of freshly collected urine from 332 patients with chronic kidney disease, diabetes, cardiovascular disease, and hypertension were distributed to manufacturers to perform urine albumin measurements according to the respective instructions for use for each procedure. Frozen aliquots were used for measurements by the IDMS procedure. An error model was used to determine imprecision and bias components. RESULTS Median differences between the largest positive and negative biases vs IDMS were 45%, 37%, and 42% in the concentration intervals of 12-30 mg/L, 31-200 mg/L, and 201-1064 mg/L, respectively. Biases varied with concentration for most procedures and exceeded ± 10% over the concentration interval for 14 of 16 quantitative procedures. Mean biases ranged from -35% to 34% at 15 mg/L. Dilution of samples with high concentrations introduced bias for 4 procedures. The combined CV was >10% for 5 procedures. It was not possible to estimate total error due to dependence of bias on concentration. CVs for sample-specific influences were 0% to 15.2%. CONCLUSIONS Bias was the dominant source of disagreement among routine measurement procedures. Consequently, standardization efforts will improve agreement among results. Variation of bias with concentration needs to be addressed by manufacturers.
منابع مشابه
Toward standardization of insulin immunoassays.
BACKGROUND Measurement of circulating insulin may improve the classification and management of diabetes mellitus and assist in treating people with insulin resistance. METHODS A work group convened by the American Diabetes Association evaluated results for a panel of 39 single donor sera measured by 10 commercial insulin methods from 9 manufacturers against an isotope dilution-liquid chromato...
متن کاملState-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry.
BACKGROUND The recent interest of clinical laboratories in developing serum testosterone assays based on isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) stems from the lack of accuracy of direct immunoassays. In this study, we assessed the accuracy and state of standardization (traceability) of 4 published ID-LC-MS/MS procedures in a method comparison with an ID-ga...
متن کاملFeasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry.
BACKGROUND Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotop...
متن کاملQuantitative detection of trichloroacetic acid in human urine using isotope dilution high-performance liquid chromatography-electrospray ionization tandem mass spectrometry.
The chemical disinfection of drinking water to control microbial contaminants results in the formation of disinfection byproducts (DBPs). The volatile trihalomethanes and the nonvolatile haloacetic acids (HAAs) are the most prevalent DBPs. It is important to monitor human exposure to HAAs because of their potential adversehealth effects, such as cancer. Among the HAAs, urinary trichloroacetic a...
متن کاملDetermination of creatinine in human urine with flow injection tandem mass spectrometry.
BACKGROUND/AIMS Excretion of urinary compounds in spot urine is often estimated relative to creatinine. For the growing number of liquid chromatography-tandem mass spectrometry (LC-MS/MS) assays of urine-excreted molecules, a fast and accurate method for determination of creatinine is needed. METHODS A high-throughput flow injection tandem mass spectrometry method for exact quantitation of cr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 60 3 شماره
صفحات -
تاریخ انتشار 2014