Correlation of IVC Diameter and Collapsibility Index With Central Venous Pressure in the Assessment of Intravascular Volume in Critically Ill Patients

نویسندگان

  • Abid Ilyas
  • Wasib Ishtiaq
  • Salman Assad
  • Haider Ghazanfar
  • Salman Mansoor
  • Muhammad Haris
  • Aayesha Qadeer
  • Aftab Akhtar
چکیده

OBJECTIVE The objective of our study is to assess the correlation between inferior vena cava (IVC) diameters, central venous pressure (CVP) and the IVC collapsibility index for estimating the volume status in critically ill patients. METHODS This cross-sectional study used the convenient sampling of 100 adult medical intensive care unit (ICU) patients for a period of three months. Patients ≥ 18 years of age with an intrathoracic central venous catheter terminating in the distal superior vena cava connected to the transducer to produce a CVP waveform were included in the study. A Mindray diagnostic ultrasound system model Z6 ultrasound machine (Mindray, NJ, USA) was used for all examinations. An Ultrasonic Transducer model 3C5P (Mindray, NJ, USA) for IVC imaging was utilized. A paired sampled t-test was used to compute the p-values. RESULTS A total of 32/100 (32%) females and 68/100 (68%) males were included in the study with a mean age of 50.4 ± 19.3 years. The mean central venous pressure maintained was 10.38 ± 4.14 cmH2O with an inferior vena cava collapsibility index of 30.68 ± 10.93. There was a statistically significant relation among the mean CVP pressure, the IVC collapsibility index, the mean maximum and minimum IVC between groups as determined by one-way analysis of variance (ANOVA) (p < 0.001). There was a strong negative correlation between CVP and IVC collapsibility index (%), which was statistically significant (r = -0.827, n = 100, p < 0.0005). A strong positive correlation between CVP and maximum IVC diameter (r = 0.371, n = 100, p < 0.0005) and minimum IVC diameter (r = 0.572, n = 100, p < 0.0005) was found. CONCLUSION There is a positive relationship of CVP with minimum and maximum IVC diameters but an inverse relationship with the IVC collapsibility index.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

A Non-invasive Method for Assessment of Intravascular Fluid Status: Inferior Vena Cava Diameters and Collapsibility Index

OBJECTIVE To evaluate the correlation between central venous pressure (CVP) and inferior vena cava (IVC) diameters measured by ultrasonography (Ultrasound) in critically ill patients. METHODS Intubated critically ill patients were enrolled. The CVP values were measured using a U-tube manometer and were compared to the IVC diameters and collapsibility index, which were measured by bedside Ultr...

متن کامل

اندازه گیری قطر قدامی – خلفی ورید اجوف تحتانی توسط سونوگرافی به عنوان یک روش غیر تهاجمی در تخمین میزان فشار ورید مرکزی در بیماران بستری در بخش مراقبت های ویژه

Introduction:The assessment of intravascular volume in severely traumatized patients or patients admitted in ICU is very essential. At present the accurate method for estimating the intravascular volume requirement is by measuring the CVP which is an invasive method. The measurement of IVC diameter by ultrasound has been suggested as an easily available and simple method for measuring the intra...

متن کامل

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

بررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017