Natural Ventilation for the Prevention of Airborne Contagion
نویسندگان
چکیده
BACKGROUND Institutional transmission of airborne infections such as tuberculosis (TB) is an important public health problem, especially in resource-limited settings where protective measures such as negative-pressure isolation rooms are difficult to implement. Natural ventilation may offer a low-cost alternative. Our objective was to investigate the rates, determinants, and effects of natural ventilation in health care settings. METHODS AND FINDINGS The study was carried out in eight hospitals in Lima, Peru; five were hospitals of "old-fashioned" design built pre-1950, and three of "modern" design, built 1970-1990. In these hospitals 70 naturally ventilated clinical rooms where infectious patients are likely to be encountered were studied. These included respiratory isolation rooms, TB wards, respiratory wards, general medical wards, outpatient consulting rooms, waiting rooms, and emergency departments. These rooms were compared with 12 mechanically ventilated negative-pressure respiratory isolation rooms built post-2000. Ventilation was measured using a carbon dioxide tracer gas technique in 368 experiments. Architectural and environmental variables were measured. For each experiment, infection risk was estimated for TB exposure using the Wells-Riley model of airborne infection. We found that opening windows and doors provided median ventilation of 28 air changes/hour (ACH), more than double that of mechanically ventilated negative-pressure rooms ventilated at the 12 ACH recommended for high-risk areas, and 18 times that with windows and doors closed (p < 0.001). Facilities built more than 50 years ago, characterised by large windows and high ceilings, had greater ventilation than modern naturally ventilated rooms (40 versus 17 ACH; p < 0.001). Even within the lowest quartile of wind speeds, natural ventilation exceeded mechanical (p < 0.001). The Wells-Riley airborne infection model predicted that in mechanically ventilated rooms 39% of susceptible individuals would become infected following 24 h of exposure to untreated TB patients of infectiousness characterised in a well-documented outbreak. This infection rate compared with 33% in modern and 11% in pre-1950 naturally ventilated facilities with windows and doors open. CONCLUSIONS Opening windows and doors maximises natural ventilation so that the risk of airborne contagion is much lower than with costly, maintenance-requiring mechanical ventilation systems. Old-fashioned clinical areas with high ceilings and large windows provide greatest protection. Natural ventilation costs little and is maintenance free, and is particularly suited to limited-resource settings and tropical climates, where the burden of TB and institutional TB transmission is highest. In settings where respiratory isolation is difficult and climate permits, windows and doors should be opened to reduce the risk of airborne contagion.
منابع مشابه
بررسی پتانسیل تهویه طبیعی بخشهای مختلف بیمارستانی دربیمارستانهای تابعه دانشگاه علوم پزشکی تهران در سال 1393
Background and aims: The current conventional effective elements on transporting or reducing of airborne aerosols and building indoor air quality are natural ventilation systems. Natural ventilation is supplying fresh air and cooling down by replacing ambient air which is one of the effective parameter on social hygiene and health aspect through controlling airborne pathogens and their relate...
متن کاملتعیین اثر بخشی حالات مختلف سامانه تهویه بر کاهش میزان مواجهه شغلی کارکنان درمانی با بیوآئروسل ها
Background & Objectives : Hospital indoor air contains a wide range of airborne pathogenic bioaerosols which have a significant impact on health care staff’ health and welfare. The aim of this study was to assess the effects of ventilation system types on occupational exposure of the health care staffs to airborne bioaerosols in the isolation room based on the patient bed arrangements and...
متن کاملExposure of school children to alpha particles
Background: A substantial part of the public’s natural radiation dose is due to the inhalation of radon gas. Most of the exposure occurs indoors where the airborne concentration of radon and its decay products is usually higher than outdoors. Materials and Methods: Radon activity concentration has been measured twice in 50 classrooms in 5 levels (10 each) during summer and winter using solid-st...
متن کاملCase Study of Airborne Pathogen Dispersion Patterns in Emergency Departments with Different Ventilation and Partition Conditions
The prevention of airborne infections in emergency departments is a very important issue. This study investigated the effects of architectural features on airborne pathogen dispersion in emergency departments by using a CFD (computational fluid dynamics) simulation tool. The study included three architectural features as the major variables: increased ventilation rate, inlet and outlet diffuser...
متن کاملتاثیر تهویه بر تراکم آلایندههای بیولوژیک هوا در یک اتاق بیمار مسلول
Background: Ventilation plays a crucial role in reducing the number of air transmitted pathogens in isolated rooms. Determination of the suitable type of ventilation system and the proper ventilating rate has always been a challenge. Patients’ bed arrangement and the location of the staff are also expected to influence the occupational exposure of the staffs’ to harmful airborne particles. The...