On the Equivalence of the 12-lead Ecg and the Vcg Representations of the Cardiac Electrical Activity
نویسنده
چکیده
The electrocardiography (ECG) and vectocardiography (VCG) both describe the same phenomena: the temporal changes of the surface potentials resulting from cardiac electrical field. The ECG uses 12 leads positioned as it was found optimal from the medical point of view during a hundred years of practice. The VCG uses 3 channels connected to the psuedoorthogonal leads that placement is determined by the orthogonality of main Cartesian axes in consequence a three-dimensional recording is performed. This paper is devoted to the experimental verification of the likeness of the data provided by both recording techniques. Two different transforms re-mapping the ECG to the VCG domain and viceversa were studied with use of the set of 125 simultaneous ECG and VCG signals from the CSE Multilead Database. One of the possible technical interests of transforming the ECG signals to the VCG domain is reducing the data volume thanks to eliminating the information redundancy typical for ECG. Our results demonstrate that the forward and inverse transform has no perfect reconstruction property and some extent of distortion should be considered when applying this technique to the signal compression.
منابع مشابه
Spatiotemporal representation of cardiac vectorcardiogram (VCG) signals
BACKGROUND Vectorcardiogram (VCG) signals monitor both spatial and temporal cardiac electrical activities along three orthogonal planes of the body. However, the absence of spatiotemporal resolution in conventional VCG representations is a major impediment for medical interpretation and clinical usage of VCG. This is especially so because time-domain features of 12-lead ECG, instead of both spa...
متن کاملCan orthogonal lead indicators of propensity to atrial fibrillation be accurately assessed from the 12-lead ECG?
AIMS When analyzing P-wave morphology, the vectorcardiogram (VCG) has been shown useful to identify indicators of propensity to atrial fibrillation (AF). Since VCG is rarely used in the clinical routine, we wanted to investigate if these indicators could be accurately determined in VCG derived from standard 12-lead ECG (dVCG). METHODS ECG and VCG recordings from 21 healthy subjects and 20 pat...
متن کاملMacroscopic Visualization of the Heart Electrical Activity Via an Algebraic Computer Model
In this study, a mathematical model is developed based on algebraic equations which is capable of generating artificially normal events of electrocardiogram (ECG) signals such as P-wave, QRS complex, and T-wave. This model can also be implemented for the simulation of abnormal phenomena of electrocardiographic signals such as ST-segment episodes (i.e. depression, elevation, and sloped ascending...
متن کاملAdaptive Filtering Strategy to Remove Noise from ECG Signals Using Wavelet Transform and Deep Learning
Introduction: Electrocardiogram (ECG) is a method to measure the electrical activity of the heart which is performed by placing electrodes on the surface of the body. Physicians use observation tools to detect and diagnose heart diseases, the same is performed on ECG signals by cardiologists. In particular, heart diseases are recognized by examining the graphic representation of heart signals w...
متن کاملAdaptive Filtering Strategy to Remove Noise from ECG Signals Using Wavelet Transform and Deep Learning
Introduction: Electrocardiogram (ECG) is a method to measure the electrical activity of the heart which is performed by placing electrodes on the surface of the body. Physicians use observation tools to detect and diagnose heart diseases, the same is performed on ECG signals by cardiologists. In particular, heart diseases are recognized by examining the graphic representation of heart signals w...
متن کامل