Beam Diagnostic by outside Beam Chamber Fields*
نویسندگان
چکیده
Fields induced by a beam and penetrated outside the beam pipe can be used for a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can work as a beam pickup. This has very small beam-coupling impedance and avoids complications of having a feed-through. The signal can be reasonably high at low frequencies. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. Such kind of diagnostic can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source. FIELDS OUTSIDE THE BEAM PIPE
منابع مشابه
Assessment of an Unshielded Electron Field Diode Dosimeter for Beam Scanning in Small- to Medium-Sized 6 MV Photon Fields
Introduction Radiotherapy planning systems require many percentage depth dose (PDD) and profile measurements and there are various dosimeters that can be used to obtain these scans. As dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (EFD) in these fields is of interest. The aim of this work was to investigate the ...
متن کاملBeam Collimation during Lumbar Spine Radiography: A Retrospective Study
Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology practice. Lack or inadequate collimation results in excessive radiation dose to patients and deterioration image quality.Objective: To assess the quality of beam collimation dur...
متن کاملQuantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam
Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...
متن کاملEffects of Transverse Beam Size in Beam Position Monitors∗
The fields produced by a long beam with a given transverse charge distribution in a homogeneous vacuum chamber are studied. Signals induced by the displaced finitesize beam on electrodes of a beam position monitor (BPM) are calculated and compared to those from a pencil beam. The non-linearities and corrections to BPM signals due to a finite transverse beam size are calculated for an arbitrary ...
متن کاملEffects of External Magnetic Fields on the Photoelectron Emission from a Copper Beam Chamber
Applying magnetic fields around a beam chamber seems to be one of the effective methods to suppress the generation of electron cloud due to photoelectrons and, therefore, the beam size blow up of the positron beam observed at the KEKB. In order to investigate the effective magnetic field configuration and to estimate the necessary strength of it, the photoelectron current at the center of a tes...
متن کامل