Fluorometric method for phenylalanine microplate assay adapted for phenylketonuria screening.

نویسندگان

  • N S Gerasimova
  • I V Steklova
  • T Tuuminen
چکیده

We adapted the method of McCaman and Robins for fluorometry of phenylalanine to a microplate assay for routine phenylketonuria screening. Sensitivity is 15 mumol/L for the plasma assay and 30 mumol/L for the dried blood-spot assay, with CV less than 10% for both assays. Results for human plasma by microplate assay correlated well (r = 0.99) with results of amino acid analyzer determination of phenylalanine. When measurements are performed in an automated reader, the microplate assay has considerable advantages over conventional measurements in cuvettes: smaller volumes of reagents and automation enabling high throughput and convenience. Because the described method is a quantitative one, we can postulate that, compared with the semiquantitative Guthrie inhibition bioassay, this microplate assay is more reliable, easier to perform, and about twofold less costly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phenylketonuria screening with a fluorometric microplate assay.

A fluorometric assay in microtitre plates for the screening of phenylketonuria was evaluated and adapted to a neonatal screening programme. Using this assay, it is possible to determine quantitatively the phenylalanine concentration in dried blood spots on filter paper. The test exhibited a linear calibration curve with a good slope as well as sufficient precision and accuracy in the statistica...

متن کامل

Rapid diagnosis of phenylketonuria by quantitative analysis for phenylalanine and tyrosine in neonatal blood spots by tandem mass spectrometry.

A new method for quantifying specific amino acids in small volumes of plasma and whole blood has been developed. Based on isotope-dilution tandem mass spectrometry, the method takes only a few minutes to perform and requires minimal sample preparation. The accurate assay of both phenylalanine and tyrosine in dried blood spots used for neonatal screening for phenylketonuria in North Carolina suc...

متن کامل

A Simple Phenylalanine Method for Detecting Phenylketonuria in Large Populations of Newborn Infants.

338 PRINCIPLE T HE INHIBITION of growth of Bacillus subtilis ATCC 6051 by B-2-thienylalanine in a minimal culture medium is prevented by phenylalanine, phenylpyruvic acid, and phenyllactic acid.l* This finding has permitted the development of a convenient agar diffusion microbial assay for phenylketonuria (PKU), employing small filter paper discs, impregnated with blood or urine, placed upon th...

متن کامل

New Enzymatic Colorimetric Method for the Quantitative Determination of Phenylalanine in Dry-Blood Spots

Phenylketonuria (PKU) is an autosomal recessive disorder, which is characterized by severe mental retardation, microcephaly and seizures. The symptoms of this disease can be prevented if detected soon after birth. Therefore, blood Phenylalanine (Phe) measurement is essential for the early diagnosis, treatment and dietary monitoring of PKU patients. The goal of this research was to introduce a r...

متن کامل

A manual fluorometric paper disc method for detecting phenylketonuria.

THE MICROBIOLOGIC PROCEDURE of Guthrie and Susi (1) is probably the most widely used screening technic for detecting phenylketonuria. The method of McCaman and Robins (2) and its modifications by Wong et al. (3) and Hsia et at. (4), as well as that of La Du and Michael (5) are the chemical procedures generally used as confirmatory tests. Hill et at. (6) have adapted the McCaman procedure to the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 10  شماره 

صفحات  -

تاریخ انتشار 1989