The appearance of dural sealants under MR imaging.

نویسندگان

  • P E Tarapore
  • P Mukherjee
  • P V Mummaneni
  • C P Ames
چکیده

Dural sealants are an adjunct to obtain watertight closure after intradural procedures. This study aims to characterize the appearance on MR imaging of 3 commonly employed dural sealants: fibrin glue, PEGH, and BSAG. To this end, patients who underwent spinal intradural procedures that included the use of dural sealant during closure were identified retrospectively. Post-operative data on 15 patients, including complications such as pseudomeningocele formation and infection, were gathered. The appearance of dural sealants on follow-up MR imaging scans within 3 days of surgery was analyzed. Fifteen patients were identified (5 with fibrin glue, 5 with PEGH, and 5 with BSAG applied during closure) with appropriately timed post-operative MR imaging scans. All 3 substances were identifiable based on anatomic location and imaging characteristics on post-operative MR imaging in standard T1, T1 PGFS, and T2 FSE. Definite differentiation between CSF and fibrin glue or PEGH was not possible with the T1 or T1 PGFS, or with the T2 FSE. Differences in intensity between CSF and BSAG were also not significant on either T1 sequence, but they were statistically significant on the T2 FSE. All patients had an uneventful post-operative course, and no patients developed post-operative pseudomeningocele at 30 days. This study concludes that water-based dural sealants such as fibrin glue and PEGH are difficult to differentiate from CSF on standard T1, T1 PGFS and T2 FSE, while BSAG is easily recognized on the T2 FSE. Recognition of water-based sealants therefore requires communication between the neurosurgeon and the neuroradiologist to avoid post-operative misidentification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partially recanalized chronic dural sinus thrombosis: findings on MR imaging, time-of-flight MR venography, and contrast-enhanced MR venography.

BACKGROUND AND PURPOSE The imaging appearance of chronic, partially recanalized dural sinus thrombosis has been incompletely described. We sought to more fully characterize the imaging findings of this entity on MR imaging, time-of-flight MR venography (TOF-MRV), and elliptic centric-ordered contrast-enhanced MR venography (CE-MRV). MATERIALS AND METHODS From a data base of patients with cere...

متن کامل

Normal appearance of arachnoid granulations on contrast-enhanced CT and MR of the brain: differentiation from dural sinus disease.

PURPOSE To determine the imaging appearance and frequency with which arachnoid granulations are seen on contrast-enhanced CT and MR studies of the brain. METHODS We retrospectively reviewed 573 contrast-enhanced CT scans and 100 contrast-enhanced MR studies of the brain for the presence of discrete filling defects within the venous sinuses. An anatomic study of the dural sinuses of 29 cadaver...

متن کامل

Pressure Mapping and Hemodynamic Assessment of Intracranial Dural Sinuses and Dural Arteriovenous Fistulas with 4D Flow MRI.

The feasibility of 4D flow MR imaging to visualize flow patterns and generate relative pressure maps in the dural venous sinus in healthy subjects (n = 60) and patients with dural arteriovenous fistulas (n = 7) was investigated. Dural venous drainage was classified based on torcular Herophili anatomy by using 4D flow MR imaging-derived angiograms and magnitude images. Subjects were scanned in a...

متن کامل

Changes of Cortisol and Glucose Concentrations in Rats Exposed to MR Imaging Field

Background: MR imaging is one of the best diagnostic modalities in medicine. During an MR imaging examination, three types of field are employed to produce images. Various experimental studies have been performed about the effects of each single type of field but only few studies are available on their combination to generate MR imaging. The main objective of this research work is to study the ...

متن کامل

MR imaging features of acute mastoiditis and their clinical relevance.

BACKGROUND AND PURPOSE MR imaging is often used for detecting intracranial complications of acute mastoiditis, whereas the intratemporal appearance of mastoiditis has been overlooked. The aim of this study was to assess the imaging features caused by acute mastoiditis in MR imaging and their clinical relevance. MATERIALS AND METHODS Medical records and MR imaging findings of 31 patients with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 2012