MDCT in emergency radiology: is a standardized chest or abdominal protocol sufficient for evaluation of thoracic and lumbar spine trauma?
نویسندگان
چکیده
OBJECTIVE The objective of our study was to assess the diagnostic performance of a standardized 4-MDCT trauma protocol for the evaluation of the thoracic and lumbar spine in patients with multiple injuries. MATERIALS AND METHODS Eighty-two patients with multiple injuries underwent MDCT for the chest and abdomen using a standardized 4-MDCT trauma protocol (collimation, 4 x 2.5 mm). Secondary reconstructions targeted to the spine were performed (slice width, 3 mm; reconstruction interval, 1.5 mm). All spinal fractures were additionally scanned using a collimation of 4 x 1 mm, and these images served as the standard of reference for fracture classification. An additional 50 patients with no spinal fracture served as the control group. A total of 65 major spinal fractures were present in 55 of the patients with multiple injuries. Two observers (observer 1 and observer 2) independently evaluated all CT data for spinal fractures using a 5-point confidence scale, classified the different fracture types, and rated the image quality of spinal structures on axial images and multiplanar reformations. RESULTS Image quality for axial images was excellent in 80% and in 68% using 4 x 1 mm and 4 x 2.5 mm collimation, respectively. Image quality of the multiplanar reformations was excellent in 75% and good in 65% using 4 x 1 mm and 4 x 2.5 mm collimation, respectively. Spinal fractures were detected by observer 1 and observer 2 with a sensitivity and specificity of 98% and 97% and of 97% and 97%, respectively. Interobserver agreement regarding the confidence scale for fracture detection was substantial (kappa = 0.80), and agreement between the different imaging protocols for fracture classification was excellent for observer 1 (kappa = 0.95) and observer 2 (kappa = 0.97). CONCLUSION Accurate evaluation of the thoracolumbar spine is possible with targeted image reconstruction based on a standardized 4-MDCT trauma protocol of the chest and abdomen.
منابع مشابه
ارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی
Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&rsquo...
متن کاملA Study on the Agreement Rate of CT-Scan Interpretation of the Cervical Spine Trauma Patients Between the Reports of Emergency Medicine Residents and Radiologist in "Shohadaye 7Tir Hospital"
Aim: The purpose of this study was to determine the rate of agreement between CT scan interpretations of cervical spine trauma patients between emergency medicines and radiology physicians. Materials and Methods: This cross-sectional analytical study was conducted in Shohadaye Haft-e Tir Hospital, Tehran, Iran. The 408 CT scans for patients with cervical spine trauma registered by the Emergency...
متن کاملEvaluation of PERSH Criteria to Avoid Unnecessary Chest X-ray in Patients with Blunt Chest Trauma: A Qualitative Study
Background: Chest X-rays (CXRs) are traditionally performed to determine intra-thoracic injuries in all blunt chest trauma patients in Shahid Bahonar hospital in Kerman. As there are some disadvantages upon CXR and radiation exposure, therefore, this study aimed to evaluate the role of CXR in the diagnosis of intra-thoracic injuries caused by any blunt chest trauma. Me...
متن کاملO18: In Hospital Management of Child with Road Trauma
Trauma is the most common cause of mortality and morbidity in pediatric population. Caring for the injured child requires special knowledge, precise management, and scrupulous attention to details. All clinicians who are responsible for the care of a pediatric trauma patient, including pediatricians, pediatric emergency room clinicians, and trauma surgeons, must be familiar with every tenet of ...
متن کاملLocal-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran
Background:The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate. Â Objective: The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 183 4 شماره
صفحات -
تاریخ انتشار 2004