Baselines are often chosen by visual inspection of their effect on selected spectra. A more objective procedure for choosing baseline correction algorithms and their parameter values for use in statistical analysis is presented. When the goal of the baseline correction is spectra with a pleasing appearance, visual inspection can be a satisfactory approach. If the spectra are to be used in a statistical analysis, objectivity and reproducibility are essential for good prediction. Variations in baselines from dataset to dataset means we have no guarantee that the best-performing algorithm from one analysis will be the best when applied to a new dataset. This paper focuses on choosing baseline correction algorithms and optimizing their parameter values based on the performance of the quality measure from the given analysis. Results presented in this paper illustrate the potential benefits of the optimization and points out some of the possible pitfalls of baseline correction.
منابع مشابه
Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملDevelopment of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase
Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase ...
متن کاملSimultaneous spectrophotometric determination of ampicillin and penicillin in human plasma using multivariate calibration
An analytical methodology based on spectrophotometric and partial least squares (PLS) algorithm for thesimultaneous determination of ampicillin and penicillin in human plasma was developed and validated. Themultivariate model was developed as a binary calibration model and it was built and validated with anindependent set of synthesis and real samples in presence of matrix. It is shown how a de...
متن کاملUV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma
Resolution of binary mixtures of theophylline (THEO), montelukast (MKST) and loratadine (LORA) with minimum sample pretreatment and without analyte separation has been successfully achieved by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV–Vis ...
متن کاملUV-Vis Spectrophotometry and Multivariate Calibration Method for Simultaneous Determination of Theophylline, Montelukast and Loratadine in Tablet Preparations and Spiked Human Plasma
Resolution of binary mixtures of theophylline (THEO), montelukast (MKST) and loratadine (LORA) with minimum sample pretreatment and without analyte separation has been successfully achieved by multivariate spectrophotometric calibration, together with partial least-squares (PLS-1), principal component regression (PCR) and hybrid linear analysis (HLA). Data of analysis were obtained from UV–Vis ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied spectroscopy
دوره 64 9 شماره
صفحات -
تاریخ انتشار 2010