Ratings of perceived exertion in braille: validity and reliability in production mode.

نویسندگان

  • J P Buckley
  • R G Eston
  • J Sim
چکیده

OBJECTIVES (a) To assess the validity and reliability of producing and reproducing a given exercise intensity during cycle ergometry using a braille version of Borg's standard 6-20 rating of perceived exertion (RPE) scale, and (b) to determine whether the exercise responses of blind participants, at a given produced RPE, were similar to those reported in recognised guidelines for sighted subjects. METHODS Ten healthy registered blind volunteer participants (four women, six men; mean (SD) age 23.2 (9.0) years) performed an initial graded exercise cycle test to determine maximal heart rate (HRMAx) and maximal oxygen uptake (VO2MAX). Three trials of three exercise bouts at RPEs 9, 11, and 13 were then performed in random order on three separate days of the same week, with expired air and heart rate measured continuously. Each exercise bout was followed by 10 minutes of rest. The validity of the scale as a means of producing different exercise intensities was assessed using a two factor (RPE x trial) repeated measures analysis of variance. Intertrial reliability was assessed using intraclass correlation coefficients (ICC) and the bias +/-95% limits of agreement (95%LoA) procedure. RESULTS Participants reported no difficulty in using the braille RPE scale. When asked to produce exercise intensities equating to RPE 9, 11, and 13, they elicited mean %VO2MAX values of 47%, 53%, and 63% respectively. Analysis of variance showed no significant differences in either %HRMAx or %VO2MAX between trials at each of the three RPEs, but there was a significant difference (p<0.001) in both %HRMAx and %VO2MAX between the three RPE levels. All pairwise comparisons of the three different RPEs were significantly different (p<0.016). The ICC between the second and third trial for %HRMAx was significant (p <0.05) for all three RPEs. Similarly for %VO2MAX, the ICC was significant for RPE 9 and 11 but not 13. The 95%LoA decreased for both %HRMAx and %VO2MAX with each successive trial. CONCLUSIONS Blind participants were successful in using a braille RPE scale to differentiate exercise intensity on a cycle ergometer. In every trial at RPE 13, all participants achieved %HRMAX and %VO2MAX levels, which fell within the recommendedrange for developing cardiorespiratory fitness. Using %HRMAx as a judge of intertrial reliability, the participants were able to repeat similar exercise intensities after two trials at each of the three RPEs (9, 11,13). The same was true for RPE 9 and 11, when %VO2MAX was used as a judge, but further trials were required to achieve similar reliability at RPE 13. A braille RPE scale can be used by healthy blind people during cycle ergometry, with similar effect to the visual analogue scale recommended for use in healthy sighted people.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of adult omni perceived exertion scales for elliptical ergometry.

This investigation examined the validity of newly developed Adult OMNI Elliptical Ergometer Ratings of Perceived Exertion Scales. 60 men and women performed a graded exercise test on an elliptical ergometer. Oxygen consumption (VO2), heart rate (HR), and ratings of perceived exertion were recorded at each stage from the Borg 15 Category scale and two different OMNI scales. One scale employed an...

متن کامل

The effects of using bench press and leg curl resistance exercise during rest interval on rating of perceived exertion, blood lactate and quantity of leg extension performance in bodybuilders

The purpose of this study was to investigate the effects of using upper (Bench press) and lower body (Leg curl) exercise during rest interval on rating of perceived exertion (RPE), lactate production and quantity of lower body performance (Leg extension) with 75% 1RM (repetition maximum). 15 resistance trained men (age 20.9±1.9 years, height 175.6 ±4.5 cm and weight 74.8±5.2 kg) took part in fo...

متن کامل

Concurrent validity and interobserver reliability of the EPInfant pediatric perceived exertion rating scale among healthy Chilean children.

The objective of this study was to determine the validity and reliability of the EPInfant pediatric perceived exertion rating scale among Chilean children. Children aged 8-12 years old were selected; their heart rate, perceived exertion and workload were recorded during two consecutive Chester tests performed with a one week interval. Pearson's r coefficient and the intraclass correlation coeff...

متن کامل

Reliability and Validity of the OMNI-Vibration Exercise Scale of Perceived Exertion.

UNLABELLED This study examined reliability and concurrent validity of the newly developed OMNI-vibration exercise scale (OMNI-VIBRO) to measure Ratings of Perceived Exertion (RPE) during vibration exercise in twenty recreationally active students (12 males and 8 females). The criterion variables were muscle activity of the Vastus Medialis (VM), Vastus Lateralis (VL), Biceps Femoris (BF), and Me...

متن کامل

Validity and reliability of the perceived benefits/barriers scale of physical activity among Iranian elderly

Abstract Background: The purpose of this study was investigating the validity and reliability of Persian version of perceived benefits/barriers of physical activity in Iranian elderly. Methods: 388 elderly subjects (up to 60 years) completed demographic characteristics questionnaire, Exercise Benefits/Barriers (EBBS) and Yale physical activity scale. Results: Persian version of EBBS showed nine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of sports medicine

دوره 34 4  شماره 

صفحات  -

تاریخ انتشار 2000