Time- and temperature-dependent stability of growth factor peptides in human autologous serum eye drops.
نویسندگان
چکیده
PURPOSES To develop a step-by-step production method for human autologous serum (AS) eye drops that was broadly compliant with US Food and Drug Administration requirements for reinjection of processed biological substances. To determine optimum storage conditions for AS eye drops by measuring the concentration of growth factor peptides (GFP) as a function of storage temperature and storage duration. METHODS AS derived from the blood of 3 healthy male volunteers was produced using a closed, vacuum-driven, cascade-filtration system under sterile, low-pyrogen conditions. In-process controls included methods for monitoring protein electrophoretic mobility and degradation rate and the content of free hemoglobin and endotoxin. Stability of transforming growth factor beta1, substance P, nerve growth factor, calcitonin gene-related peptide, insulin-like growth factor 1, and epidermal growth factor was evaluated at -15 degrees C, +4 degrees C, +25 degrees C, +37 degrees C, and +42 degrees C at different time intervals (hours to weeks). The main outcome measures were the concentrations of GFP, endotoxin, and lipid peroxidation by-products (a proxy measure for protein degradation) in dilute AS. RESULTS The stability of GFP varies: transforming growth factor beta1, nerve growth factor, epidermal growth factor, and insulin-like growth factor 1 were more temperature and time resistant, but substance P and calcitonin gene-related peptide significantly degraded at +4 degrees C in 24 hours. Endotoxin and lipid peroxidation by-products were not significantly increased by processing. CONCLUSIONS This pilot study developed a closed, cascade-filtration system that was an effective method for the production of high-quality, low-pyrogen AS. The processing method broadly complied with Food and Drug Administration requirements for reinjection of biological substances. Variable GFP stability was observed at +4 degrees C and above. For clinical use, AS should be packaged in daily-use containers, which should be stored frozen; the container in active use should be refrigerated between doses.
منابع مشابه
Autologous serum eye drops for ocular surface disorders
Tears have antimicrobial, nourishing, mechanical, and optical properties. They contain components such as growth factors, fibronectin, and vitamins to support proliferation, migration, and differentiation of the corneal and conjunctival epithelium. A lack of these epitheliotrophic factors—for example, in dry eye, can result in severe ocular surface disorders such as persistent epithelial defect...
متن کاملMicrofluidic Autologous Serum Eye-Drops Preparation as a Potential Dry Eye Treatment
Dry eye is a problem in tearing quality and/or quantity and it afflicts millions of persons worldwide. An autologous serum eye-drop is a good candidate for dry eye treatment; however, the eye-drop preparation procedures take a long time and are relatively troublesome. Here we use spiral microchannels to demonstrate a strategy for the preparation of autologous serum eye-drops, which provide bene...
متن کامل[Use of autologous serum in ophthalmic practice].
OBJECTIVE To establish a protocol for the use of autologous serum in the ophthalmic practice. METHODS Personal experience and a literature review. RESULTS The use of autologous serum, in eye drop form, has been reported as a new treatment for several ocular surfaces diseases. These products have biomechanical and biochemical properties similar to normal tears. They contain components such a...
متن کاملEffect of Autologous Serum Eye Drops in Patients with Sjögren Syndrome-related Dry Eye: Clinical and In Vivo Confocal Microscopy Evaluation of the Ocular Surface.
AIM To evaluate in vivo changes after therapy using autologous serum (AS) eye drops in Sjögren's syndrome (SS)-related dry eyes by confocal microscopy. PATIENTS AND METHODS In this study, 24 patients with SS-related dry eyes [12 in AS eye drop therapy and 12 in artificial tear (AT) therapy] and 24 healthy volunteers were recruited. Ocular Surface Disease Index (OSDI), central corneal thicknes...
متن کاملConservative treatment for late-onset bleb leaks after trabeculectomy with mitomycin C in patients with ocular surface disease
BACKGROUND Sodium hyaluronate and autologous serum eye drops are used to treat ocular surface disease (OSD) and are reported to prevent and treat late-onset bleb leaks following trabeculectomy with mitomycin C. In this study, we evaluated the efficacy of a combination of sodium hyaluronate and autologous serum eye drops and treatment for obstructive meibomian gland dysfunction as a therapy for ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cornea
دوره 28 2 شماره
صفحات -
تاریخ انتشار 2009