Percutaneous Coronary Intervention Under Cover of Left Ventricular Assist Device (Impella 2.5).

نویسندگان

  • Imran Iftikhar
  • Hamid Sharif Khan
  • Azhar Mahmood Kayani
  • Hassan Shahzad
چکیده

Impella 2.5 is a temporary left ventricular assist device that is being increasingly used in high risk Percutaneous Coronary intervention (PCI). It reduces the cardiac workload and provides assistance to myocardium and vital organs in states of severe left ventricular dysfunction and cardiogenic shock. We report the first case of successful percutaneous coronary stenting performed in a high risk patient using impella 2.5. A 65-year old diabetic and hypertensive male with a known double vessel coronary artery disease and a reduced left ventricular function (ejection fraction, 20%) was admitted with intractable angina. He was on optimal medical treatment for 2 months. His coronary angiogram done 2 months back had revealed double vessel coronary artery disease (subtotally occluded co-dominant left circumflex and moderate 60% stenosis in left anterior descending artery and a normal co-dominant right coronary artery). He was considered a high risk both for Coronary Artery Bypass Graft (CABG) surgery and PCI due to co-morbidities and reduced left ventricular function. As he had failed a trial of optimal medical therapy and the cardiac surgeon's reluctance for surgery, the patient and his family was counseled for high risk PCI with left ventricular assist device using the impella 2.5.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Complication Due to Impella 2.5 Device (Superficial Femoral Artery Thrombosis): Managed Successfully with Novel Aspiration Thrombectomy Catheter (Pronto V3)

The Impella recover LP 2.5 is a percutaneous left ventricular assist device (LVAD) recently approved for use in patients undergoing high risk percutaneous coronary intervention (PCI) and also in cases of cardiogenic shock. There is limited evidence available in literature about its safety, especially with regards to the incidence of local vascular complications, their management and long-term i...

متن کامل

A prospective feasibility trial investigating the use of the Impella 2.5 system in patients undergoing high-risk percutaneous coronary intervention (The PROTECT I Trial): initial U.S. experience.

OBJECTIVES We sought to evaluate the safety and feasibility of the Impella 2.5 system (Abiomed Inc., Danvers, Massachusetts) in patients undergoing high-risk percutaneous coronary intervention (PCI). BACKGROUND The Impella 2.5 is a miniaturized percutaneous cardiac assist device, which provides up to 2.5 l/min forward flow from the left ventricle into the systemic circulation. METHODS In a ...

متن کامل

Role of percutaneous coronary minimalist intervention in the management of acute ST-segment elevation myocardial infarction.

1. Smalling RW, Cassidy DB, Barrett R, et al. Improved regional myocardial blood flow, left ventricular unloading, and infarct salvage using an axial-flow, transvalvular left ventricular assist device. A comparison with intra-aortic balloon counterpulsation and reperfusion alone in a canine infarction model. Circulation 1992;85:1152–9. 2. Henriques JP, Remmelink M, Baan J Jr., et al. Safety and...

متن کامل

A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: the PROTECT II study.

BACKGROUND Although coronary artery bypass grafting is generally preferred in symptomatic patients with severe, complex multivessel, or left main disease, some patients present with clinical features that make coronary artery bypass grafting clinically unattractive. Percutaneous coronary intervention with hemodynamic support may be feasible for these patients. Currently, there is no systematic ...

متن کامل

Initial experience with the Impella Recover LP 2.5 micro-axial pump in patients undergoing high-risk coronary angioplasty.

INTRODUCTION The Impella LP 2.5 device is a new percutaneous left ventricular assist device, an intravascular micro-axial blood pump designed for short term circulatory support in conditions characterized by profoundly reduced ventricular function. Percutaneous coronary intervention (PCI) is increasingly being used in patients who have severely compromised left ventricular contractility and com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the College of Physicians and Surgeons--Pakistan : JCPSP

دوره 25 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2015