Measurement of Crestal Cortical Bone Thickness at Implant Site: A Cone Beam Computed Tomography Study.

نویسندگان

  • Ajai Gupta
  • Suprabha Rathee
  • Jaihans Agarwal
  • Renu B Pachar
چکیده

AIM Dental implants have emerged as a new treatment modality for the majority of patients complaining of missing teeth. Bone quantity and bone quality are among various factors which ensure the longevity of dental implant in the patient's mouth. The assessment of cortical bone thickness of the outer layer and the cancellous bone density by cone beam computed tomography (CBCT) has proved beneficial for the patient. This study aimed at presurgical measurement of crestal bone thickness at various implant sites using CBCT images. MATERIALS AND METHODS This study was conducted in the Department of Prosthodontics in the year 2015. It included 218 patients who wanted to replace missing teeth. Patients were subjected to CBCT scan using NewTom CBCT machine operating at 120 kVp and 5 mA with a resolution of 0.1 × 0.1 × 0.1 mm3. New Net Technologies (NNT) software with a slice thickness of 0.1 mm was used in this study. A total of 780 implant sites were identified on images of 218 patients. In all patients, the measurement of crestal bone thickness in the region of implant site was performed with NNT software. The buccolingual measurement of crestal bone was done in cross sections obtained after CBCT Results: Out of 218 patients, males were 110 and females were 108. The difference between gender was nonsignificant (p > 0.05). Out of 780 implant sites, 370 were in the maxilla and 410 were in mandible. The difference was nonsignificant (p > 0.05). Out of 780 implant sites, 210 were in anterior maxilla and 160 were in the posterior maxilla. Totally, 235 sites were in anterior mandible and 175 were in the posterior mandible. The distribution was nonsignificant (p = 0.15). The mean crestal bone thickness in anterior maxilla was 0.82 mm, in posterior maxilla was 0.76 mm, in anterior mandible was 1.08 mm, and in posterior mandible was 1.18 mm. The difference among regions was significant (p = 0.01). CONCLUSION The highest thickness of cortical bone was observed in posterior mandible followed by anterior mandible, anterior maxilla, and posterior maxilla. Thus, considering the less cortical thickness in the posterior maxillary region, the implant placement should be done with proper attention. CLINICAL SIGNIFICANCE Dental implant is the need of the hour. It is beneficial to patients in terms of longer survival rates. With CBCT, all measurements, such as bone quality and quantity have become easy because of three-dimensional nature. This has proved to be beneficial in the analysis of cortical bone thickness as well as measuring the distance from anatomical structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique

Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...

متن کامل

Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients

BACKGROUND/PURPOSE Resonance frequency analysis (RFA) is clinically used in dentistry to access the stiffness of dental implants in surrounding bone. However, the clear advantages and disadvantages of this method are still inconclusive. The aim of this study was to investigate and compare implant stability quotient (ISQ) values obtained from RFA with parameters obtained from a cone beam compute...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

A comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study

Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...

متن کامل

Influence of bone parameters on peri-implant bone strain distribution in the posterior mandible

OBJECTIVES The success rate of dental implants depends on the type of bone at the implant site. The purpose of the present study was to investigate the effects of the bone parameters at the implant-placement site on peri-implant bone strain distributions. STUDY DESIGN The morphologies and bone densities of seventy-five potential implant sites in the posterior mandible were measured using comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 18 9  شماره 

صفحات  -

تاریخ انتشار 2017