Optimizing parameter choice for FSL-Brain Extraction Tool (BET) on 3D T1 images in multiple sclerosis
نویسندگان
چکیده
BACKGROUND Brain atrophy studies often use FSL-BET (Brain Extraction Tool) as the first step of image processing. Default BET does not always give satisfactory results on 3DT1 MR images, which negatively impacts atrophy measurements. Finding the right alternative BET settings can be a difficult and time-consuming task, which can introduce unwanted variability. AIM To systematically analyze the performance of BET in images of MS patients by varying its parameters and options combinations, and quantitatively comparing its results to a manual gold standard. METHODS Images from 159 MS patients were selected from different MAGNIMS consortium centers, and 16 different 3DT1 acquisition protocols at 1.5 T or 3T. Before running BET, one of three pre-processing pipelines was applied: (1) no pre-processing, (2) removal of neck slices, or (3) additional N3 inhomogeneity correction. Then BET was applied, systematically varying the fractional intensity threshold (the "f" parameter) and with either one of the main BET options ("B" - bias field correction and neck cleanup, "R" - robust brain center estimation, or "S" - eye and optic nerve cleanup) or none. For comparison, intracranial cavity masks were manually created for all image volumes. FSL-FAST (FMRIB's Automated Segmentation Tool) tissue-type segmentation was run on all BET output images and on the image volumes masked with the manual intracranial cavity masks (thus creating the gold-standard tissue masks). The resulting brain tissue masks were quantitatively compared to the gold standard using Dice overlap coefficient (DOC). Normalized brain volumes (NBV) were calculated with SIENAX. NBV values obtained using for SIENAX other BET settings than default were compared to gold standard NBV with the paired t-test. RESULTS The parameter/preprocessing/options combinations resulted in 20,988 BET runs. The median DOC for default BET (f=0.5, g=0) was 0.913 (range 0.321-0.977) across all 159 native scans. For all acquisition protocols, brain extraction was substantially improved for lower values of "f" than the default value. Using native images, optimum BET performance was observed for f=0.2 with option "B", giving median DOC=0.979 (range 0.867-0.994). Using neck removal before BET, optimum BET performance was observed for f=0.1 with option "B", giving median DOC 0.983 (range 0.844-0.996). Using the above BET-options for SIENAX instead of default, the NBV values obtained from images after neck removal with f=0.1 and option "B" did not differ statistically from NBV values obtained with gold-standard. CONCLUSION Although default BET performs reasonably well on most 3DT1 images of MS patients, the performance can be improved substantially. The removal of the neck slices, either externally or within BET, has a marked positive effect on the brain extraction quality. BET option "B" with f=0.1 after removal of the neck slices seems to work best for all acquisition protocols.
منابع مشابه
Brain Activity Map Extraction from Multiple Sclerosis Patients Using Resting-State fMRI Data Based on Amplitude of Low Frequency Fluctuations and Regional Homogeneity Analysis
Introduction: Multiple Sclerosis (MS) is the most common non-traumatic neurological diseases of young adults. MS often reported during ages 20-62. MS affects the various anatomical parts of the central nervous system. Up to 65% of multiple sclerosis patients MS patients suffer from various problems, such as fatigue, depression, pain and sleep disorders. Unlike MRI, that only sh...
متن کاملAlgorithm for brain extraction on Magnetic Resonance Images T1 using Morphological 3D Transformations
In this paper a 3D morphological composition of transformations for brain extraction on brain Magnetic Resonance Images T1 (MRI T1) is presented. The proposal makes use of two morphological connected transformations, the lower leveling and a family of the viscous alternating sequential filters (VASFs). The properties of these operators -which consist in the control of the reconstruction process...
متن کاملQuantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging
Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...
متن کاملQuantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation
Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...
متن کاملThe Optimization of Magnetic Resonance Imaging Pulse Sequences in Order to Better Detection of Multiple Sclerosis Plaques
Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 61 4 شماره
صفحات -
تاریخ انتشار 2012