LC-MS/MS Method for Serum Creatinine: Comparison with Enzymatic Method and Jaffe Method

نویسندگان

  • Meixian Ou
  • Yunxiao Song
  • Shuijun Li
  • Gangyi Liu
  • Jingying Jia
  • Menqi Zhang
  • Haichen Zhang
  • Chen Yu
  • Valquiria Bueno
چکیده

Accurate quantification of creatinine (Cre) is important to estimate glomerular filtration rate (GFR). Differences among various methods of Cre quantification were previously noted. This study aims to develop a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for serum Cre and compare this method with clinical routine methods. LC-MS/MS analysis was performed on API 4000 triple quadrupole mass spectrometer coupled with an Agilent 1200 liquid chromatography system. After adding isotope-labeled Cre-d3 as internal standard, serum samples were prepared via a one-step protein precipitation with methanol. The LC-MS/MS method was compared with frequently used enzymatic method and Jaffe method. This developed method, with a total run time of 3 min, had a lower limit of quantification of 4.4 μmol/L, a total imprecision of 1.15%-3.84%, and an average bias of 1.06%. No significant matrix effect, carryover, and interference were observed for the LC-MS/MS method. The reference intervals of serum Cre measured by LC-MS/MS assay were 41-79 μmol/L for adult women, and 46-101 μmol/L for adult men. Using LC-MS/MS as a reference, the enzymatic method showed an average bias of -2.1% and the Jaffe method showed a substantial average bias of 11.7%. Compared with the LC-MS/MS method, significant negative bias was observed for the enzymatic and Jaffe methods in hemolytic and lipimic samples. We developed a simple, specific, and accurate LC-MS/MS method to analyze serum Cre. Discordance existed among different methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.

We evaluated a new, simple, enzymatic kinetic method from Wako Chemicals GmbH in comparison with a kinetic Jaffé method by using isotope dilution-mass spectrometry (ID-MS) as a reference method. An ID-MS-calibrated serum standard was used. Both the enzymatic and the Jaffé method correlated well with ID-MS, except for sera with high concentrations of bilirubin. Ethyl acetoacetate, acetone, and g...

متن کامل

Routine serum creatinine measurements: how well do we perform?

BACKGROUND The first aim of the study was to investigate the accuracy and intra-laboratory variation of serum creatinine measurements in clinical laboratories in Flanders. The second purpose was to check the effect of this variation in serum creatinine concentration results on the calculated estimated glomerular filtration rate (eGFR) and the impact on classification of patients into a chronic ...

متن کامل

A Risk Assessment of the Jaffe vs Enzymatic Method for Creatinine Measurement in an Outpatient Population

BACKGROUND The Jaffe and enzymatic methods are the two most common methods for measuring serum creatinine. The Jaffe method is less expensive than the enzymatic method but is also more susceptible to interferences. Interferences can lead to misdiagnosis but interferences may vary by patient population. The overall risk associated with the Jaffe method depends on the probability of misclassifica...

متن کامل

Applicability of common reference intervals for serum creatinine concentrations to the Croatian population.

BACKGROUND In accordance with an ongoing activity for worldwide harmonization based on traceability in laboratory methods, the goal of this study was to validate the applicability of recommended "common" reference intervals for serum creatinine concentrations using a specific enzymatic method to the Croatian population. METHODS The reference group consisted of 240 healthy subjects (120 males ...

متن کامل

New liquid chromatography-tandem mass spectrometry method for routine TDM of vancomycin in patients with both normal and impaired renal functions and comparison with results of polarization fluoroimmunoassay in light of varying creatinine concentrations.

A new LC-MS/MS method with simple sample extraction and a relatively short period of vancomycin analysis for routine therapeutic drug monitoring was developed and validated. 50μL serum was precipitated using 20μL 33% trichloroacetic acid and 0.5mol/L NH4OH was added to increase pH before analysis. A RP BEH C18, 1.7μm, 2.1×50mm column maintained at 30°C and tobramycin as internal standard were u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015