Automafed FluorometricCreatine KinaseAssay. Measurement of 100-Fold NormalActivitywithoutSerum Dilution
نویسندگان
چکیده
Creatine kinase (EC 2.7.3.2) activity can be measured fluorometrically by coupling the reaction product, creatine, to ninhydrin at alkaline pH. We have automated this procedure to develop an accurate and precise method, which requires 0.1 ml of sample and can be performed at 60 tests per hour. By using an abbreviated incubation time and a dia!yzer in the iiay, we have extended the analytical range to 100 times normal serum activity without sample dilution. The dialyzer also eliminates the nonspecific protein fluorescence of the sample. An additional advantage of the method is the reduced cost of reagents In comparison to similar procedures. Serum blanks should be analyzed whenever serum creatine is abnormally high, especially In cases of severe renal failure.
منابع مشابه
Dilution of plasma with Tris buffer increases measured catecholamines in plasma.
We investigated the effects of dilution of plasma samples on the measured concentrations of catecholamines. Diluting samples of human plasma 10-, 50-, and 100-fold with Tris buffer (100 mol/L, pH 8.6) improved analytical recovery of internal standards, suggesting that it decreases the commonly observed inhibition of methylation in radioenzymatic assays of catecholamines in plasma. However, the ...
متن کاملSerologic study on leptospiral infection in sheep in Ahvaz, southwestern Iran
To investigate the seroprevalence of leptospiral infection in sheep in Ahvaz, southwestern Iran, bloodsamples were taken from 181 female sheep. Sera were stored at -20°C until use. They were initially screenedat serum dilution of 1:100 against six live antigens of Leptospira interrogans serovars pomona, canicola,hardjo, ballum, icterohaemorrhagiae, grippotyphosa using the microscopic agglutinat...
متن کاملNew Perspectives in the Renin-Angiotensin-Aldosterone System (RAAS) I: Endogenous Angiotensin Converting Enzyme (ACE) Inhibition
Angiotensin-converting enzyme (ACE) inhibitors represent the fifth most often prescribed drugs. ACE inhibitors decrease 5-year mortality by approximately one-fifth in cardiovascular patients. Surprisingly, there are reports dating back to 1979 suggesting the existence of endogenous ACE inhibitors, which endogenous inhibitory effects are much less characterized than that for the clinically admin...
متن کاملFood allergy and anaphylaxis – 2043. Poor dilutional linearity of food allergen specific IgE measurement by immunocap in samples with high total IgE
Methods 31 deidentified subjects with tIgE 1000-5000 kU/L (Group A) and 10 subjects with tIgE >5000 kU/L (Group B) had sIgE measurement for egg, milk, wheat, peanut, and soybean by ImmunoCap from undiluted and 4 serial two-fold dilutions using manufacturer supplied diluent. Myeloma IgE was prepared at an initial dilution of 1:28 and then 7 serial two-fold dilutions were performed. tIgE percenta...
متن کاملCalibration curves for real-time PCR.
BACKGROUND Despite the increasing use of real-time PCR in the diagnosis and management of viral infections, there are no published studies adequately addressing the optimum number of calibrators, the number of replicates of each calibrator, and the frequency with which calibration needs to be repeated. This study was designed to address these issues. METHODS Cycle threshold data (ABI 7700) wa...