Pulse-Driven Magnetoimpedance Sensor Detection of Cardiac Magnetic Activity

نویسندگان

  • Shinsuke Nakayama
  • Kenta Sawamura
  • Kaneo Mohri
  • Tsuyoshi Uchiyama
چکیده

This study sought to establish a convenient method for detecting biomagnetic activity in the heart. Electrical activity of the heart simultaneously induces a magnetic field. Detection of this magnetic activity will enable non-contact, noninvasive evaluation to be made. We improved the sensitivity of a pulse-driven magnetoimpedance (PMI) sensor, which is used as an electric compass in mobile phones and as a motion sensor of the operation handle in computer games, toward a pico-Tesla (pT) level, and measured magnetic fields on the surface of the thoracic wall in humans. The changes in magnetic field detected by this sensor synchronized with the electric activity of the electrocardiogram (ECG). The shape of the magnetic wave was largely altered by shifting the sensor position within 20 mm in parallel and/or perpendicular to the thoracic wall. The magnetic activity was maximal in the 4th intercostals near the center of the sterna. Furthermore, averaging the magnetic activity at 15 mm in the distance between the thoracic wall and the sensor demonstrated magnetic waves mimicking the P wave and QRS complex. The present study shows the application of PMI sensor in detecting cardiac magnetic activity in several healthy subjects, and suggests future applications of this technology in medicine and biology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gamma Irradiation Effect on Asymmetric Giant Magnetoimpedance of Co68.15Fe4.35Si12.5B15 Amorphous Alloy

The giant magneto impedance (GMI) effect is a large variation in the electrical impedance of a magnetic conductor when subjected to a static magnetic field. The sensitivity to the direction (AGMI) and magnitude of applied  magnetic field    and also linearity levels   of this  effect are three important parameters in magnetic sensors application. A suitable annealing procedure can be used to ac...

متن کامل

Detection of P300 brain waves using a Magneto-Impedance sensor

We have previously reported a study on brain activity detection in occipital region using a picotesla-scale MagnetoImpedance (MI) sensor. Based on past studies, the target of the present study was to review the performance of MI sensor on parietal region brain activity detection. Human brain magnetic field is extremely weak, in order to detect the faint magnetic field, we constructed an MI meas...

متن کامل

The Disturbing Effect of the Stray Magnetic Fields on Magnetoimpedance Sensors

The disturbing effect of the stray magnetic fields of Fe-based amorphous ribbons on the giant magnetoimpedance (GMI) sensor has been investigated systematically in this paper. Two simple methods were used for examining the disturbing effect of the stray magnetic fields of ribbons on the GMI sensor. In order to study the influence of the stray magnetic fields on the GMI effect, the square-shaped...

متن کامل

Improvement of the off-diagonal magnetoimpedance sensor white noise

This work deals with the analysis of noise sources of the off-diagonal magneto-impedance sensor with stressannealed amorphous ribbon. This experimental analysis shows that the equivalent magnetic noise spectral density is mostly due to the electronic conditioning circuitry that operates the sensor. The electronic noise was then reduced with employment of an improved excitation-detection techniq...

متن کامل

Preparation and characterization magnetic polypyrrole composite microspheres decorated with copper(II) as a sensing platform for electrochemical detection of Carbamazepine

With a facile solvothermal technique, Ssynthesis and application of Fe3O4@PPy–CuIIcomposite microspheres in the carbon ionic liquid matrix have been reported as highly sensitive sensors for voltammetric determination of Carbamazepine (CBZ). The morphology, crystal phase and structure of synthesized The nanocomposite structure was confirmed by routine methods such as transmission electron micros...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011