Impact of diabetes mellitus on vessel response in the drug-eluting stent era: pooled volumetric intravascular ultrasound analyses.

نویسندگان

  • Kenji Sakata
  • Katsuhisa Waseda
  • Teruyoshi Kume
  • Hiromasa Otake
  • Daisaku Nakatani
  • Paul G Yock
  • Peter J Fitzgerald
  • Yasuhiro Honda
چکیده

BACKGROUND Exaggerated neointimal hyperplasia is considered as the primary mechanism for increased restenosis in patients with diabetes mellitus (DM) treated with bare-metal stent. However, the vessel response in DM and non-DM treated with different drug-eluting stents (DES) has not been systematically evaluated. METHODS AND RESULTS We investigated 3D intravascular ultrasound (postprocedure and 6 to 9 months) in 971 patients (267 with DM and 704 without DM) treated with sirolimus- (n=104), paclitaxel- (n=303), zotarolimus- (n=391), or everolimus- (n=173) eluting stents. Volumetric data were standardized by length as volume index (VI). At postprocedure, lumen VI at the stented segment was significantly smaller in DM than in non-DM, whereas vessel VI was similar between the 2 groups. At follow-up, neointimal obstruction and maximum cross-sectional narrowing (neointimal area/stent area) were not significantly different between the 2 groups with no interaction for the DES type. Consequently, lumen VI was smaller in DM than in non-DM at follow-up. In the reference segments, residual plaque burden at postprocedure was significantly greater in DM than in non-DM, although change in lumen VI was similar between the 2 groups. The arterial responses at the reference segments also showed no interaction for the DES type. CONCLUSIONS DM and non-DM lesions showed similar vessel response in both in-stent and reference segments regardless of the DES type. In the DES era, the follow-up lumen in DM patients seems to be determined primarily by the smaller lumen at postprocedure rather than exaggerated neointima within the stent or plaque proliferation at the reference segments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kommerell diverticulum associated with aberrant left subclavian artery and right-sided aortic arch.

SEARCH) study. Circulation 2004;109:1366–70. 30. Iijima R, Ndrepepa G, Mehilli J, Markwardt C, Bruskina O, Pache J et al. Impact of diabetes mellitus on long-term outcomes in the drug-eluting stent era. Am Heart J 2007;154:688–93. 31. Kawamoto T, Okura H, Koyama Y, Toda I, Taguchi H, Tamita K et al. The relationship between coronary plaque characteristics and small embolic particles during coro...

متن کامل

Characterization of plaque prolapse after drug-eluting stent implantation in diabetic patients: a three-dimensional volumetric intravascular ultrasound outcome study.

OBJECTIVES The aim of this research was to evaluate the plaque prolapse (PP) phenomenon after bare-metal (BMS) and drug-eluting stent (DES) implantation in patients with diabetes mellitus using 3-dimensional volumetric intravascular ultrasound (IVUS). BACKGROUND Plaque prolapse has been observed in up to 22% of patients treated with BMS. Diabetic patients have a larger atherothrombotic burden...

متن کامل

Impact of Polymer Formulations on Neointimal Proliferation After Zotarolimus-Eluting Stent With Different Polymers

Background—Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Methods and Results—Data were obtained from t...

متن کامل

Impact of polymer formulations on neointimal proliferation after zotarolimus-eluting stent with different polymers: insights from the RESOLUTE trial.

BACKGROUND Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. METHODS AND RESULTS Data were obtained from...

متن کامل

Vascular effects of sirolimus-eluting versus bare-metal stents in diabetic patients: three-dimensional ultrasound results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial.

OBJECTIVES A predefined intravascular ultrasound (IVUS) substudy was performed to evaluate the vascular effects of sirolimus-eluting stent (SES) versus bare-metal stent (BMS). BACKGROUND The Diabetes and Sirolimus-Eluting Stent (DIABETES) trial is a prospective, multicenter, randomized, controlled trial aimed at demonstrating the efficacy of the SES compared with BMS in diabetic patients. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 5 6  شماره 

صفحات  -

تاریخ انتشار 2012