Positive end-expiratory pressure attenuates hemodynamic effects induced by an overload of inspiratory muscles in patients with COPD
نویسندگان
چکیده
BACKGROUND Inspiratory muscle training (IMT) using a Threshold® device is commonly used to improve the strength and endurance of inspiratory muscles. However, the effect of IMT, alone or with positive end-expiratory pressure (PEEP), on hemodynamic parameters in patients with chronic obstructive pulmonary disease (COPD) remains unknown. OBJECTIVE To assess the effects of an overload of inspiratory muscles using IMT fixed at 30% of the maximal inspiratory pressure (MIP), and IMT associated with 5 cmH2O of PEEP (IMT + PEEP), on the echocardiographic parameters in healthy subjects and patients with COPD. METHODS Twenty patients with COPD (forced expiratory volume in 1 second 53.19±24.71 pred%) and 15 age-matched healthy volunteers were evaluated using spirometry, MIP, the COPD assessment test (CAT), and the modified Medical Research Council (mMRC) dyspnea scale. The E- (fast-filling phase) and A- (atrial contraction phase) waves were evaluated at the tricuspid and mitral valves during inspiration and expiration in the following sequence: at basal conditions, using IMT, and using IMT + PEEP. RESULTS Patients with COPD had reduced MIPs versus the control group. Ten patients had CAT scores <10 and 12 patients had mMRC scores <2. E-wave values at the mitral valve were significantly decreased with IMT during the inspiratory phase in both groups. These effects were normalized with IMT + PEEP. During the expiratory phase, use of IMT + PEEP normalized the reduction in E-wave values in the COPD group. During inspiration at the tricuspid valve, reduction in E-wave values during IMT was normalized by IMT + PEEP in COPD group. During the expiratory phase, the value of the E-waves was significantly reduced with overload of the inspiratory muscles in both groups, and these effects were normalized with IMT + PEEP. A-waves did not change under any conditions. CONCLUSION Acute hemodynamic effects induced by overloading of the inspiratory muscles were attenuated and/or reversed by the addition of PEEP in COPD patients.
منابع مشابه
Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery
Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...
متن کاملIntrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure.
Deviation of end-expiratory lung volume from the elastic equilibrium volume of the respiratory system is recognized as a cardinal feature in mechanically-ventilated patients with severe chronic obstructive pulmonary disease (COPD) and acute ventilatory failure (AVF). The presence of dynamic hyperinflation implies that alveolar pressure remains positive throughout expiration. At the end of the e...
متن کاملThe Effect Of External Positive End-Expiratory Pressure On Extubation Rate In Patients With Intrinsic Positive End-Expirtory Pressure
Intubation and mechanical ventilation are associated with several major complications despite their lifesaving potential. It is thus important to discontinue mechanical ventilation and remove the endotracheal tube from the patient when spontaneous ventilation is sustained. The process of discontinuing mechanical ventilation may constitute a major clinical challenge and become the principal caus...
متن کاملEfficacy of noninvasive CPAP in COPD with acute respiratory failure.
Dynamic hyperinflation and the development of intrinsic positive end-expiratory pressure (PEEPi) are commonly observed in patients with severe chronic obstructive pulmonary disease (COPD) in acute respiratory failure. Previous studies have shown that externally applied PEEP reduces PEEPi and its adverse effects in mechanically-ventilated COPD patients. The purpose of this study was to determine...
متن کامل"Intrinsic" PEEP (PEEPi): role of expiratory muscles.
In normal subjects breathing at rest, lung volume at end-expiration corresponds with the elastic equilibrium volume, or relaxation volume (Vr), of the respiratory system. If expiratory duration is not long enough, then inspiration may begin before the system has returned to Vr, such that end-expiratory lung volume is higher than Vr. This condition is named dynamic pulmonary hyperinflation and "...
متن کامل