Catastrophic Femoral Head-Stem Trunnion Dissociation Secondary to Corrosion.

نویسندگان

  • Laura Matsen Ko
  • Antonia F Chen
  • Gregory K Deirmengian
  • William J Hozack
  • Peter F Sharkey
چکیده

BACKGROUND Modular femoral heads provide procedural enhancement by allowing accurate restoration of hip offset and limb-length equalization. However, corrosion may lead to adverse local tissue reactions. Severe trunnion corrosion can also lead to femoral head dissociation and catastrophic implant failure following primary total hip arthroplasty. METHODS We describe 5 cases, from our institution, in which the femoral head became dissociated from the femoral stem trunnion secondary to severe corrosion. Possible causes are evaluated. RESULTS Demographic commonalities among the 5 patients included a body mass index (BMI) of ≥30 kg/m(2) and male sex. All femoral heads were made of cobalt-chromium alloy and were larger-diameter implants (≥36 mm). Four of the 5 patients had a femoral head that increased the neck length above the default on a so-called standard head and 3 of the 5 had a stem with a 127° neck-shaft angle. CONCLUSIONS Although dissociation of the femoral head from the femoral trunnion following total hip arthroplasty is exceedingly rare, the prevalence may increase with longer follow-up. The dissociation is likely related to multiple factors, including a BMI of ≥30 kg/m(2), male sex, and corrosion resulting from the use of a larger metal head with a neck length of greater than the default and a stem with high offset. It is critical that surgeons be able to recognize this mode of implant failure and appropriately prepare to remove the femoral component during revision surgery. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spontaneous modular femoral head dissociation complicating total hip arthroplasty.

Modular femoral heads have been used successfully for many years in total hip arthroplasty. Few complications have been reported for the modular Morse taper connection between the femoral head and trunnion of the stem in metal-on-polyethylene bearings. Although there has always been some concern over the potential for fretting, corrosion, and generation of particulate debris at the modular junc...

متن کامل

Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head.

BACKGROUND Gross trunnion failure (GTF) is a rare complication in total hip arthroplasty (THA) reported across a range of manufacturers. Specific lots of the Stryker low friction ion treatment (LFIT) anatomic cobalt chromium alloy (CoCr) V40 femoral head were recalled in August 2016. In part, the recall was based out of concerns for disassociation of the femoral head from the stem and GTF. ME...

متن کامل

Corrosion and adverse tissue reaction after modular unipolar hip hemiarthroplasty

Modern unipolar hip hemiarthroplasty, commonly used for displaced femoral neck fracture, is now modular, with both a variable length cobalt-chromium adapter-sleeve and large femoral head. Patients with these modular components may develop symptomatic trunnion corrosion, with elevated serum metal levels. We report the case of an 82-year-old woman, 5.5 years after a modular unipolar hip hemiarthr...

متن کامل

Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty.

This study examines how taper design affects corrosion and fretting at the head trunnion surface. All hip prostheses retrieved between 1999 and 2013 with 28mm/+0 heads were selected, resulting in 44 cobalt-chrome-on-polyethylene implants, representing six taper designs. Mean implantation time: 8.9±3.7years. The femoral head tapers were scored for fretting and corrosion using the Goldberg scale ...

متن کامل

Late Nontraumatic Dissociation of the Femoral Head and Trunnion in a Total Hip Arthroplasty

Background. Modular total hip arthroplasties are increasingly popular because customisation allows optimal restoration of patient biomechanics. However, the introduction of component interfaces provides greater opportunities for failure. We present a case of late nontraumatic dissociation of the head-neck interface, more than 10 years after insertion. Case Description. A 58-year-old woman had a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 98 16  شماره 

صفحات  -

تاریخ انتشار 2016