OBJECTIVE The coaxial circle system helps prevent heat loss during surgery, and it also acts as a humidifier. This study aimed to compare the coaxial breathing system and the conventional system in their ability to warm and moisturize inhaled gases, and we also analyzed lung function protection and saccharin clearance time in patients who underwent tympanomastoidectomy (TMT) with the aid of these two systems. MATERIALS AND METHODS Forty adult patients of ASA physical status I-II were scheduled for elective TMT. A standard volume-dependent ventilator setting was used to establish normocapnia. The coaxial circle system was used in the treated group (n=20), whereas the conventional circuit system was used in the control group (n=20). Saccharin clearance, VC (vital capacity), FRC (functional residual capacity), FEV1 (forced expiratory volume in 1 second), airway pressure, relative humidity and temperature of inspired gas, body temperature and adverse and hemodynamic effects were measured at different perioperative periods. RESULTS The relative humidity (mg H2O Lt -1) of inspired gas in the treated group was higher than in the control group at 5, 15, 30, 45, 60 and 90 minutes after anesthesia induction. The temperature of inspired gas (Centigrade) in the treated group was higher than in the control group (p<0.05) after 5, 10, 15, 30, 45, and 90 minutes of anesthesia. Postoperative saccharin clearance time was lower than before the operation in the treated group (p<0.05). Postoperative FRC was lower than preoperative FRC in the study and control groups (p<0.05). CONCLUSION The coaxial circle system decreased postoperative saccharin clearance time and increased postoperative FRC, relative humidity and the temperature of inspired fresh gas, without any adverse perioperative effects in patients who underwent TMT.
منابع مشابه
Modeling the Circle of Willis Using Electrical Analogy Method under both Normal and Pathological Circumstances
Background and objective: The circle of Willis (COW) supports adequate blood supply to the brain. The cardiovascular system, in the current study, is modeled using an equivalent electronic system focusing on the COW.Method: In our previous study we used 42 compartments to model whole car- diovascular system. In the current study, nevertheless, we extended our model by using 63 compartments to m...
متن کاملA Developed Structure of Step-Up DC/DC Converter by Using Coupled Inductor and Active Clamped Circuit
In this paper, a new structure of step-up dc-dc converter by using coupled inductor and active-clamped circuit is proposed. The proposed converter generates high voltage gain in comparison with the conventional dc-dc converters. Duo to using active-clamped circuit in the proposed topology the voltage stress on main switch is reduced. In addition the zero voltage switching (ZVS) in ON-state of m...
متن کاملThe Geometry of Karbandi in Persian Architecture; Response to the Challenges of Conventional and Stellar Karbandi
Karbandi is one of the original and ancient arched elements in Persian architecture which is formed based on a network with harmonic geometry and in addition to architectural function, it also has structural behavior. However, there are ambiguities about the geometry of this architectural element that should be addressed with targeted research. One of these ambiguities is to determine how the g...
متن کاملDesign, Construction and Comparison of a Sensorless Driver Circuit for Switched Reluctance Motor
In the presented paper, a sensorless driver circuit is designed, constructed and tested to control two types of three-phase Switched Reluctance Motor (SRM). The presented control algorithm has three steps. In the first step, the SRM is controlled by an open-loop method. In the second step, mathematical model of the SRM phase, motor parameters and flux-current-rotor position relation are used in...
متن کاملDetection of interruptions in the breathing gas of ventilated anaesthetized patients.
Interruption of the breathing gas to a ventilated anaesthetized patient due to accidental disconnection or anaesthesia system malfunction may have serious consequences if not detected quickly. A series of tests which covers the range of foreseeable mechanical problems was developed and used to test the performance of three breathing gas interruption monitors, two commercially available and one ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Eurasian journal of medicine
دوره 43 2 شماره
صفحات -
تاریخ انتشار 2011