Hyperglycemia and cystic fibrosis alter respiratory fluid glucose concentrations estimated by breath condensate analysis.

نویسندگان

  • Emma H Baker
  • Nicholas Clark
  • Amanda L Brennan
  • Donald A Fisher
  • Khin M Gyi
  • Margaret E Hodson
  • Barbara J Philips
  • Deborah L Baines
  • David M Wood
چکیده

In animals, glucose concentrations are 3-20 times lower in lung lining fluid than in plasma. In humans, glucose concentrations are normally low (<1 mmol/l) in nasal and bronchial fluid, but they are elevated by inflammation or hyperglycemia. Furthermore, elevated bronchial glucose is associated with increased respiratory infection in intensive care patients. Our aims were to estimate normal glucose concentrations in fluid from distal human lung sampled noninvasively and to determine effects of hyperglycemia and lung disease on lung glucose concentrations. Respiratory fluid was sampled as exhaled breath condensate, and glucose was measured by chromatography with pulsed amperometric detection. Dilution corrections, based on conductivity, were applied to estimate respiratory fluid glucose concentrations (breath glucose). We found that breath glucose in healthy volunteers was 0.40 mmol/l (SD 0.24), reproducible, and unaffected by changes in salivary glucose. Breath-to-blood glucose ratio (BBGR) was 0.08 (SD 0.05). Breath glucose increased during experimental hyperglycemia (P < 0.05) and was elevated in diabetic patients without lung disease [1.20 mmol/l (SD 0.69)] in proportion to hyperglycemia [BBGR 0.09 (SD 0.06)]. Breath glucose was elevated more than expected for blood glucose in cystic fibrosis patients [breath 2.04 mmol/l (SD 1.14), BBGR 0.29 (SD 0.17)] and in cystic fibrosis-related diabetes [breath 4.00 mmol/l (SD 2.07), BBGR 0.54 (0.28); P < 0.0001]. These data indicate that 1) this method makes a biologically plausible estimate of respiratory fluid glucose concentration, 2) respiratory fluid glucose concentrations are elevated by hyperglycemia and lung disease, and 3) effects of hyperglycemia and lung disease can be distinguished using the BBGR. This method will support future in vivo investigation of the cause and effect of elevated respiratory fluid glucose in human lung disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Excessive daytime sleepiness in patients with sleep-disordered breathing.

REFERENCES 1 Liu J, Conrad DH, Chow S, Tran VH, Yates DH, Thomas PS. Collection devices influence the constituents of exhaled breath condensate. Eur Respir J 2007; 30: 807–808. 2 Rosias PP, Robroeks CM, Niemarkt HJ, et al. Breath condenser coatings affect the measurement of biomarkers in exhaled breath condensate. Eur Respir J 2006; 28: 1036–1041. 3 Horváth I, Hunt J, Barnes PJ. Exhaled breath ...

متن کامل

Noninvasive monitoring of glucose levels: is exhaled breath the answer?

Monitoring of blood glucose levels is clinically important in the management of diseases affecting insulin secretion and resistance, most notably diabetes mellitus and cystic fibrosis. Typically, blood glucose monitoring is an invasive technique that may cause distress and discomfort, particularly in the pediatric population. Development of noninvasive methods of monitoring blood glucose is the...

متن کامل

Exhaled 8-isoprostane as a new non-invasive biomarker of oxidative stress in cystic fibrosis.

BACKGROUND Cystic fibrosis is characterised by oxidative stress in the airways. Isoprostanes are prostaglandin isomers formed by free radical catalysed peroxidation of arachidonic acid. 8-Isoprostane is increased in interstitial lung diseases, asthma, chronic obstructive pulmonary disease, and adult respiratory distress syndrome. Exhaled nitric oxide (NO) and carbon monoxide (CO) are biomarkers...

متن کامل

Lessons learned from metabolomics in cystic fibrosis

Cystic fibrosis is a mono-genetic multi-system disease; however, respiratory manifestations cause the main morbidity and mortality where chronic bacterial infections lead to bronchiectasis and ultimately respiratory failure. Metabolomics allows a relatively complete snapshot of metabolic processes in a sample using different mass spectrometry methods. Sample types used for discovery of biomarke...

متن کامل

RESPIRATORY PHYSIOLOGY Exhaled breath condensate pH and exhaled nitric oxide in allergic asthma and in cystic fibrosis

Background: It has been proposed that the pH of airway lining fluid may regulate the fractional exhaled concentration of nitric oxide (FENO) in respiratory disease. Methods: FENO, exhaled breath condensate (EBC) pH, and EBC concentrations of nitrite plus nitrate (NO2/ NO3) were compared in 12 subjects with stable asthma, 18 with stable cystic fibrosis (CF), and 15 healthy control subjects. Eigh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 102 5  شماره 

صفحات  -

تاریخ انتشار 2007