Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

نویسندگان

  • Luis M. Astudillo
  • Orlando Santana
  • Pablo A. Urbandt
  • Alexandre M. Benjo
  • Lior U. Elkayam
  • Francisco O. Nascimento
  • Gervasio A. Lamas
  • Joseph Lamelas
چکیده

OBJECTIVE We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderate, and severe Patient Prosthesis Mismatch as effective orifice area indexes of .0.85 cm(2)/m, 0.85-0.66 cm(2)/m(2), and <0.65 cm(2)/m(2), respectively. RESULTS A total of 311 bioprosthetic patients were identified. The incidence of nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 41%, 42, and 16%, respectively. Severe Patient Prosthesis Mismatch was significantly more prevalent in females (82%). In severe Patient Prosthesis Mismatch, the perfusion and the crossclamp times were considerably lower when compared with nonsignificant Patient Prosthesis Mismatch and moderate Patient Prosthesis Mismatch. Patients with severe Patient Prosthesis Mismatch had a significantly higher likelihood of spending time in the intensive care unit and a significantly longer length of stay in the hospital. Body surface area was not different in severe Patient Prosthesis Mismatch when compared with nonsignificant Patient Prosthesis Mismatch. In-hospital mortality in patients with nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 2.3%, 6.1%, and 8%, respectively. Minimally invasive surgery was significantly associated with moderate Patient Prosthesis Mismatch in 49% of the patients, but not with severe Patient Prosthesis Mismatch. CONCLUSION Severe Patient Prosthesis Mismatch is more common in females, but not in those with minimal available body surface area. Though operative times were shorter in these patients, intensive care unit and hospital lengths of stay were longer. Surgeons and cardiologists should be cognizant of these clinical predictors and complications prior to valve surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictors of Left Ventricular Mass Regression Following Aortic Valve Replacement

Method Randomized selection of 100 patients, underwent aortic valve replacement with a single type of bio-prosthesis (Medtronic Mosaic) for pure aortic stenosis. The study population showed that, 25/100 (25%) patients had prosthesis-patient mismatch of a moderate degree (indexed effective orifice area (IEOA) from 0.65 cm2/m2 0.85 cm2/m2). The effect of prosthesis-patient mismatch on the postope...

متن کامل

[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].

INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...

متن کامل

Prosthesis-patient mismatch in the transcatheter aortic valve replacement era.

In an insightful report in 1978, Rahimtoola (1) pointed to the fact that “mismatch can be considered to be present when the effective prosthetic valve area, after insertion into the patient, is less than that of a normal human valve.” He recognized that most patients have some residual aortic stenosis after aortic valve replacement and suggested that moderate or severe residual aortic stenosis ...

متن کامل

Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.

OBJECTIVE After aortic valve replacement, the effects of a small functional prosthesis on the extent and pattern of regression of left ventricular hypertrophy and on clinical outcomes may be less significant in older patients with low cardiac output requirements. The objective of this study was therefore to determine whether patient-prosthesis mismatch affects left ventricular mass regression i...

متن کامل

Factors Determining Patient-Prosthesis Mismatch after Aortic Valve Replacement – A Prospective Cohort Study

OBJECTIVE "Patient-prosthesis mismatch" (PPM) after aortic valve replacement (AVR) has been reported to increase morbidity and mortality. Although algorithms have been developed to avoid PPM, factors favouring its occurrence have not been well defined. DESIGN AND SETTING This was a prospective cohort study performed at the Medical University of Vienna. PATIENTS 361 consecutive patients who ...