Log-normal diameter distribution of Pd-based metallic glass droplet and wire

نویسندگان

  • S. Yaginuma
  • C. Nakajima
  • N. Kaneko
  • Y. Yokoyama
  • K. S. Nakayama
چکیده

We have studied the formation of Pd42.5Cu30Ni7.5P20 metallic glass droplets and wires in the gas atomization process. We demonstrate that the sizes of droplets and wires can be distinguished by the Ohnesorge number (Oh), which is the proportion of the spinnability to the capillary instability, and the diameter distributions follow a log-normal distribution function, implying cascade fragmentation. For droplets, the number significantly increases at Oh < 1 but the diameter gradually decreases. For wires, the number greatly increases at Oh > 1 while the diameter steadies below 400 nm. Further, the wire diameter is quadrupled at Oh = 16 due to the high viscosity which suppresses both capillary breakup and ligament elongation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

“One-Sided” Log-Normal Distribution of Conductances for a Disordered Quantum Wire

We develop a simple systematic method, valid for all strengths of disorder, to obtain analytically the full distribution of the conductance P g for a quasi-one-dimensional wire in the absence of electronelectron interactions. We show that in the crossover region between the metallic and insulating regimes P g is highly asymmetric, given by an essentially “one-sided” log-normal distribution. For...

متن کامل

‘One Sided’ Log-normal Distribution of Conductances of a Disordered Quantum Wire

We develop a simple systematic method, valid for all strengths of disorder, to obtain analytically for the first time the full distribution of conductance P (g) for a quasi one dimensional wire in the absence of electron-electron interaction. We show that in the crossover region between the metallic and insulating regimes, P (g) is highly asymmetric, given by an essentially ‘one sided’ log-norm...

متن کامل

Stochastic Comparisons of Probability Distribution Functions with Experimental Data in a Liquid-Liquid Extraction Column for Determination of Drop Size Distributions

The droplet size distribution in the column is usually represented as the average volume to surface area, known as the Sauter mean drop diameter. It is a key variable in the extraction column design. A study of the drop size distribution and Sauter-mean drop diameter for a liquid-liquid extraction column has been presented for a range of operating conditions and three different liquid-liquid sy...

متن کامل

Key factors affecting mechanical behavior of metallic glass nanowires

Both strengthening and weakening trends with decreasing diameter have been observed for metallic glass nanowires, sometimes even in the samples with the same chemical composition. How to reconcile the results has reminded a puzzle. Since the detailed stress state and microstructure of metallic glass nanowires may differ from each other significantly depending on preparation, to discover the int...

متن کامل

Energy and Second Law of Thermodynamics Analysis of Shower Cooling Tower with Variation in Inlet Air Temperature

A shower cooling tower (SCT) operates without fill because of salt decomposition on the fill that leads to deterioration of conventional cooling tower performance. This study presents a two-dimensional mathematical model for energy and exergy analysis of multi-diameter droplets and air interaction along with the height of the forced draft SCT, to predict the exit condition of water droplet for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015