Development of a Chinese version of the National Eye Institute Visual Function Questionnaire (CHI-VFQ-25) as a tool to study patients with eye diseases in Hong Kong.
نویسندگان
چکیده
BACKGROUND To develop a Chinese version of the National Eye Institute Visual Function Questionnaire (CHI-VFQ-25) and to test its reliability and validity in a group of patients with eye diseases in Hong Kong. METHODS The National Eye Institute Visual Function Questionnaire (NEI-VFQ) was translated into Chinese. Patients were recruited from Hong Kong, and their demographic data and visual acuity were documented. Psychometric properties of the CHI-VFQ-25, including internal consistency, test-retest reliability, item-scale correlations and construct validity were tested. RESULTS 250 patients were recruited. The mean age of the patients was 66.04 (SD 14.00). 46% of them were male. The non-response rate and the floor and ceiling numbers of the CHI-VFQ-25 were calculated. The internal consistency was high in most subscales (except the general health and driving subscales), with Cronbach alpha ranging from 0.72-0.90. The test-retest reliability was excellent (intraclass correlation coefficient >0.90). Patients with worse visual acuity had significantly lower scores on the CHI-VFQ-25 supporting construct validity. CONCLUSION The CHI-VFQ-25 is a reliable and valid tool for assessing the visual functions of Chinese patients with eye diseases in Hong Kong. Some questions had high non-response rates and should be substituted by the available alternatives.
منابع مشابه
Development of the 25-item National Eye Institute Visual Function Questionnaire.
OBJECTIVE To develop and test the psychometric properties of a 25-item version of the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). DESIGN Prospective observational cohort study of persons with 1 of 5 chronic eye diseases or low vision who were scheduled for nonurgent visits in ophthalmology practices and a reference sample of persons without eye disease. SETTING Eleven...
متن کاملAssessment of quality of life in patients with visual impairments using a new visual function questionnaire: the VFQ-J11
BACKGROUND The purpose of the present study was to assess the vision-related quality of life (QOL) of visually impaired patients using the Japanese 11-item National Eye Institute Visual Function Questionnaire (VFQ-J11). Comparisons with the 25-item version (VFQ-25) and the EuroQoL Index using a large group of patients with various degrees of impairments and various causative diseases were perfo...
متن کاملRemediating serious flaws in the National Eye Institute Visual Function Questionnaire.
PURPOSE To test the assumption that the National Eye Institute Visual Function Questionnaire (NEI VFQ) measures visual functioning, assess the validity of its subscales, and, if flawed, revise the questionnaire and derive a shortened version with sound psychometric properties. SETTING Flinders Medical Centre, Adelaide, Australia. METHODS Patients from the cataract surgery waiting list self-...
متن کاملThe Relationship Between Self-Management and Quality of Life and Visual Function in Glaucoma Patients
Introduction: Self-management positively contributes to the Quality of Life of many patients with chronic diseases. Objective: The present study aimed to investigate the relationship between self-management and the quality of life and visual performance among patients with glaucoma. Materials and Methods: The current cross-sectional and comparative study was conducted at the...
متن کاملValidation of the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25) in age-related macular degeneration.
PURPOSE Patient-reported measures of visual function are increasingly incorporated into clinical trials of new treatments for age-related macular degeneration (AMD). Limited information is available regarding the associations between distance visual acuity (VA), reading speed, or contrast sensitivity and the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25) subscales judged r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 93 11 شماره
صفحات -
تاریخ انتشار 2009