A Comparative Study of Current and Voltage Transients on a Distribution Transformer Due To Capacitor Switching

نویسندگان

  • Pawan Kumar Mehta
  • Baidehi Nanda
  • Swayam Ranjan Halder
  • Akhilesh kumar
  • Afsir Ahsan
  • Santanu Das
  • Poulomi Mitra
  • Akhilesh Kumar
چکیده

A high voltage capacitor is relatively frequently switched during the periods of the system operations. The distribution transformers are subjected to many stresses during normal and abnormal operations. In this paper we simulate a portion of the distribution network of Durgapur Steel Plant using MATLAB 7.7 and observe the effects of capacitor switching events on transformer terminal at different instants. Simulations of capacitor switching transients show significant disturbances in HV transformers which illustrate cause of transformer failure due to matching of transient frequency to the natural frequency of transformer. This paper is intended to alert the industries from the impact of first transient phenomena on transformer which is the real cause of failure of transformer of above said

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Minimization Within Static Var Compensated Distribution Systems

VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...

متن کامل

Detection of inrush current in distribution transformer using wavelet transform

Inrush currents in transformers are non-sinusoidal, high magnitude currents generated due to flux saturation in the core during energization. For protection purpose, in this paper an efficient method for detection of inrush current in distribution transformer based on wavelet transform is presented. Using this method inrush current can be discriminated from the other switching transients such a...

متن کامل

Multi-objective Based Optimization Using Tap Setting Transformer, DG and Capacitor Placement in Distribution Networks

In this article, a multi-objective function for placement of Distributed Generation (DG) and capacitors with thetap setting of Under Load Tap Changer (ULTC) Transformer is introduced. Most of the recent articles have paidless attention to DG, capacitor placement and ULTC effects in the distribution network simultaneously. Insimulations, a comparison between different modes was carried out with,...

متن کامل

Harmonic Reduction Technique Using Flying Capacitor Based Z Source Inverter for a DVR

The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...

متن کامل

Ant Colony Optimization to Shunt Capacitor Allocation in Radial Distribution Systems

This paper presents an ant colony approach optimization to shunt capacitor placement on distribution systems under capacitor switching constraints. The optimum capacitor allocation solution is found for the system of feeders fed through their transformer and not for any individual feeder. The main advantages due to capacitor installation, such as system capacity release and reduction of overall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012