Unitary rotation and gyration of pixelated images on rectangular screens.

نویسندگان

  • Alejandro R Urzúa
  • Kurt Bernardo Wolf
چکیده

In the two space dimensions of screens in optical systems, rotations, gyrations, and fractional Fourier transformations form the Fourier subgroup of the symplectic group of linear canonical transformations: U(2)F⊂Sp(4,R). Here, we study the action of this Fourier group on pixelated images within generic rectangular Nx×Ny screens; its elements here compose properly and act unitarily, i.e., without loss of information.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

 A novel approach to automatic position calibration for pixelated crystals in gamma imaging

Introduction: The position estimation in gamma detection system will have constant misplacements which can be corrected in the calibration procedure. In the pixelated crystal uniformly irradiation of detector will produce irregular shape due to position estimation errors. This image is called flood field image and is used to calibrate the position estimation. In this work we pr...

متن کامل

Free Vibration Analysis of Size-Dependent, Functionally Graded, Rectangular Nano/Micro-plates based on Modified Nonlinear Couple Stress Shear Deformation Plate Theories

In the present study, a vibration analysis of functionally graded rectangular nano-/microplates was considered based on modified nonlinear coupled stress exponential and trigonometric shear deformation plate theories. Modified coupled stress theory is a non-classical continuum mechanics theory. In this theory, a material-length scale parameter is applied to account for the effect of nanostructu...

متن کامل

بررسی دقت تشخیصی Limited Screening CT و مقایسه با CT استاندارد در تشخیص سینوزیت

Background and purpose : Çoronal ÇT scan of paranasal sinuses with contiguous images is the gold standard technique in diagnosis of sinusitis. Çonsidering the expense and high dose of radiation in conventional ÇT scan, clinical measurements and simple radiography is not enough sensitive and specific, some workers have suggested limited screening (non contiguous) instead of conventional ÇT ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics, image science, and vision

دوره 33 4  شماره 

صفحات  -

تاریخ انتشار 2016