Outdoor air ventilation rates vary considerably between and within buildings, and may be too low in some spaces. The purpose of this study was to evaluate the potential work performance benefits of increased ventilation. We analyzed the literature relating work performance with ventilation rate and employed statistical analyses with weighting factors to combine the results of different studies. The studies included in the review assessed performance of various tasks in laboratory experiments and measured performance at work in real buildings. Almost all studies found increases in performance with higher ventilation rates. The studies indicated typically a 1-3% improvement in average performance per 10 l/s-person increase in outdoor air ventilation rate. The performance increase per unit increase in ventilation was bigger with ventilation rates below 20 l/s-person and almost negligible with ventilation rates over 45 l/s-person. The performance increase was statistically significant with increased ventilation rates up to 15 l/s-person with 95% CI and up to 17 l/s-person with 90% CI. Practical Implications We have demonstrated a quantitative relationship between work performance and ventilation within a wide range of ventilation rates. The model shows a continuous increase in performance per unit increase in ventilation rate from 6.5 l/s-person to 65 l/s-person. The increase is statistically significant up to 15 l/s-person. This relationship has a high level of uncertainty; however, use of this relationship in ventilation design and feasibility studies may be preferable to the current practice, which ignores the relationship between ventilation and productivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study on the Influence of Window To Wall Ratio on Energy Consumption and Ventilation Performance in Office Building of Temperate Humid Climate: a Case Study in Rash

The natural ventilation and the energy consumption are very important characteristics in buildings. Representation of the patterns for better natural ventilation performance versus lower increase in energy consumption is significant and useful. This study is simulating an office building in the temperate and humid climate of Rasht in Iran, and calculated the annual ventilation and the energy co...

متن کامل

Investigating the Effects of Environmental Factors on Office Buildings’ Indoor Environment Quality in Iran’s Cold Climate (Case study: Kermanshah)

The inappropriate indoor environmental quality of a building causes different problems such asheadache and breathing difficulties which are called the syndrome of building sickness. These diseases reduce the efficiency of people and deteriorate the quality of their life. Studies carried out in hundreds of big office buildings across the world show that the indoor environment qualities of these ...

متن کامل

The relationship between workplace stressors with performance and mental fatigue of employees in open plan offices

Introduction: employees have a significant impact on the organization productivity and efficiency. On the other hand human performance may have effect by environmental conditions. The purpose of this research was to investigate the association between workplace environmental factors, mental fatigue, and worker performance in open plan offices. Material and Methods: This descriptive-analytical...

متن کامل

Dynamic Envelope and Control Shading Pattern to Visual Comfort of Office Building in Tehran

This work reviews the effect of parametric programming on visual performance, daylighting and shading in office buildings in Tehran-Iran and studies their influences that help not only to reduce the glare but also to promote useful daylight illuminance through promoting visual comfort. It starts by establishing a review of the effective parameters on visual comfort indices, glare indices, and d...

متن کامل

Porosity Rendering in High-Performance Architecture: Wind-Driven Natural Ventilation and Porosity Distribution Patterns

Natural ventilation is one of the most essential issues in the concept of high-performance architecture. The porosity has a lot to do with wind-phil architecture to meet high efficiency in integrated architectural design and materialization a high-performance building. Natural ventilation performance in porous buildings is influenced by a wide range of interre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Indoor air

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2006