Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay.
نویسندگان
چکیده
Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoassay, enzyme immunoassay, and liquid chromatography. The essay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods.
منابع مشابه
Radioimmunoassay, enzyme immunoassay, spectrophotometry, and gas-liquid chromatography compared for determination of phenobarbital and diphenylhydantoin.
Sera from epileptic patients were assayed for phenobarbital and diphenylhydantoin by four different analytical procedures. Quantitative results obtained by radioimmunoassay (I) and enzyme immunoassay (II) were compared to each other and to the results obtained on aliquots of the same sample by gas-liquid chromatography (III) and ultraviolet spectrophotometry (IV). For phenobarbital the correlat...
متن کاملEnzymatic immunoassay vs. gas/liquid chromatography for determination of phenobarbital and diphenylhydantoin in serum.
The antiepileptic drugs diphenylhydantoin and phenobarbital were measured in serum by a new commercially available enzyme immunoassay procedure ("EMIT," Syva Corp.). The procedure requires less than 5 min and no more than 50 mul of serum per determination. It is simple; only four steps (pipetting and diluting with an automatic pipettor-dilutor) are required before spectrophotometry. Twenty repl...
متن کاملApplication of electron spin resonance to determination of serum drug concentrations.
Displacement of spin-labeled drugs from drug-specific antibodies in human serum can be measured by use of electron spin resonance. This "spin immunoassay" has advantages of speed, simplicity, and small volume requirements over other standard techniques such as gas-liquid, liquid-liquid, or thin-layer chromatography. Unlike radioimmunoassay, there is no need to separate free and bound label and ...
متن کاملResults by fluorescent immunoassay for phenytoin compared with those by enzyme immunoassay, liquid chromatography, and discrete analysis (Dupont aca).
We describe the Ames Fluorescent Enzyme Immunoassay procedure for the detection of phenytoin in serum, and compare the results with it with those by enzyme immunoassay(EMIT), "high-pressure" liquid chromatography, and the Dupont aca. Sera from 48 patients who were receiving phenytoin were promptly analyzed in duplicate by EMIT, frozen, then assayed within four weeks by the other three methods. ...
متن کاملEnzyme immunoassay and gas--liquid chromatography compared for determination of lidocaine in serum.
Lidocaine, an anti-arrhythmic drug, was quantitated in serum by a commercially supplied enzyme immunoassay procedure. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of less than 5.0 and a between-assay coefficient of variation of less than 6.5. Regression analysis of 87 serum samples analyzed by this technique (y) and by gas-liquid chromatography (x) g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 24 4 شماره
صفحات -
تاریخ انتشار 1978