The interference effect of a mixture of magnesium, aluminium, sulfate and chloride on the atomization and vaporization of manganese in graphite furnace atomic absorption spectrometry.

نویسندگان

  • H Ince
  • S Akman
چکیده

In this study, the interference effects of Al3+, Mg2+, Cl- and SO4(2-) ions on the determination of manganese by graphite furnace atomic absorption spectrometry (GFAAS) were investigated. At first, the interferences caused by Al2(SO4)3, AlCl3, MgCl2 and MgSO4, which are the most possible major compounds for the combinations of the ions mixed, were individually considered. Then, the effects caused by mixtures containing various amounts of MgSO4 and AlCl3 were studied. If the pyrolysis temperature is below 800 degrees C, AlCl3 changes the vaporization mechanism of manganese. These interferences disappear at higher pyrolysis temperatures. At the same time, aluminum salts may cause the formation of refractory compounds between aluminum and manganese (like spinel MnAl2O4) that shift the absorption signals of manganese to higher temperatures. Magnesium sulfate, by itself, does not cause any depression of manganese signals. In fact, it acts as a modifier, preventing volatilization losses of manganese during the pyrolysis step. A conclusion was reached that detailed investigation of the interferences in a complex media is a very difficult experimental and theoretical task. To solve practical problems, one may better follow the general notions developed in GFAAS toward complex matrices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

Direct determination of zinc in plasma by graphite furnace atomic absorption spectrometry using palladium/magnesium and EDTA matrix modification with high temperature pyrolysis

High prevalence of zinc deficiency stemming frommalnutrition, gastrointestinal diseases and low dietary intake accounts for detection of zinc in plasma being a frequently requested clinical pathology assay. Serum and plasma zinc determination by graphite furnace atomic absorption spectrometry (GFAAS) has previously been hampered by significant interfering species and intolerance to high pyrolys...

متن کامل

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...

متن کامل

Tungsten coil devices in atomic spectrometry: absorption, fluorescence, and emission.

In this work, tungsten coil (W-Coil) devices are used as atomizers for electrothermal atomization atomic absorption spectrometry (ETAAS), electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS), and electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). For most cases in ETAAS and ETA-LEAFS, limits of detection (LODs) usi...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2004