Novel excitation coils for non-destructive evaluation of non-magnetic metallic structures by high-Tc dc SQUID
نویسندگان
چکیده
A non-destructive evaluation (NDE) system was set up in our laboratory. A high-Tc dc superconducting quantum interference device (dc SQUID) made from YBa2Cu3O7−δ thin film on a 24◦ bicrystal SrTiO3 substrate was adopted as the magnetic flux sensor. Novel excitation coils and a balance circuitry were proposed and employed for evaluation of multilayer aluminium structure with artificial slits in an unshielded noisy environment. Our experimental data demonstrate that the NDE system with proper location of two thin excitation coils could make full use of the dynamic range of the SQUID and enhance the spatial resolution of detection.
منابع مشابه
Optimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials
The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...
متن کاملOptimal SQUID based non-destructive test for detecting sub-surface defects with the help of advanced SQUID superconducting sensors and an experimental approach for optimal production method of these sensors from the YBCO superconductor materials
The conventional eddy current method for non-destructive inspection of welding joints has limitations that can examine defects to a certain depth below the surface of the sample and is not suitable for determining deep defects. This limitation can be overcome using the SQUID superconducting sensors. The nonstoichiometric composition of YBCO due to its superconducting temperature and desired cri...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملHigh Tc SQUID Detector for Magnetic Metallic Particles in Products
High-Tc superconducting quantum interference device (SQUID) is an ultra-sensitive magnetic sensor. After the discovery of the high-Tc superconducting materials, the performance of the high-Tc SQUID has been improved and stabilized. One strong candidate for application is a detection system of magnetic foreign matters in industrial products. There is a possibility that ultra-small metallic forei...
متن کاملRecent Developments of High-Tc Electronic Devices with Multilayer Structures and Ramp-Edge Josephson Junctions
Recent developments of electronic devices containing Josephson junctions (JJ) with high-Tc superconductors (HTS) are reported. In particular, the fabrication process and the properties of superconducting quantum interference devices (SQUIDs) with a multilayer structure and ramp-edge-type JJs are described. The JJs were fabricated by recrystallization of an artificially deposited Cu-poor precurs...
متن کامل