A computational and experimental study inside microfluidic systems: the role of shear stress and flow recirculation in cell docking.
نویسندگان
چکیده
In this paper, microfluidic devices containing microwells that enabled cell docking were investigated. We theoretically assessed the effect of geometry on recirculation areas and wall shear stress patterns within microwells and studied the relationship between the computational predictions and experimental cell docking. We used microchannels with 150 microm diameter microwells that had either 20 or 80 microm thickness. Flow within 80 microm deep microwells was subject to extensive recirculation areas and low shear stresses (<0.5 mPa) near the well base; whilst these were only presented within a 10 microm peripheral ring in 20 microm thick microwells. We also experimentally demonstrated that cell docking was significantly higher (p < 0.01) in 80 microm thick microwells as compared to 20 microm thick microwells. Finally, a computational tool which correlated physical and geometrical parameters of microwells with their fluid dynamic environment was developed and was also experimentally confirmed.
منابع مشابه
Microcirculation within grooved substrates regulates cell positioning and cell docking inside microfluidic channels.
Immobilization of cells inside microfluidic devices is a promising approach for enabling studies related to drug screening and cell biology. Despite extensive studies in using grooved substrates for immobilizing cells inside channels, a systematic study of the effects of various parameters that influence cell docking and retention within grooved substrates has not been performed. We demonstrate...
متن کاملCell docking in double grooves in a microfluidic channel.
Microstructures that generate shear-protected regions in microchannels can rapidly immobilize cells for cell-based biosensing and drug screening. Here, a two-step fabrication method is used to generate double microgrooves with various depth ratios to achieve controlled double-level cell patterning while still providing shear protection. Six microgroove geometries are fabricated with different g...
متن کاملEvaluation of Recirculation Time in Bubble Train Flow by Using Direct Numerical Simulation
In this research, hydrodynamics of the Bubble Train Flows (BTF) in circular capillaries has been investigated by Direct Numerical Simulation (DNS).The Volume of Fluid Based (VOF) interface tracking method and streamwise direction periodic boundary conditions has been applied. The results show that there exists an appropriate agreement between DNS and experimental correlation results. The re...
متن کاملA Computational Study about the Effect of Turbines Pitched Blade Attack Angle on the Power Consumption of a Stirred Tank
In this study, the stirring mechanism of shear-thinning fluids benefiting from four blades in turbulent flow is considered. The fluid is studied inside a stirred cylindrical tank with a flat bottom. The height of fluid is equal to the cylinder’s diameter and the impeller is positioned centrally. A CFD simulation has been carried out and three-dimensional turbulent flow is numerically analyzed u...
متن کاملNumerical Study of Droplet Generation Process in a Microfluidic Flow Focusing
Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical microdevices
دوره 12 4 شماره
صفحات -
تاریخ انتشار 2010