Bronchodilator aerosol administered by metered dose inhaler and spacer in subacute neonatal respiratory distress syndrome.
نویسندگان
چکیده
There is increasing evidence that bronchodilators are effective in ventilator dependent preterm infants. The effects of single doses of salbutamol (400 micrograms), ipratropium bromide (72 micrograms), and placebo (four puffs) given by metered dose inhaler and spacer (MDIS) were examined in 10 ventilated preterm infants, with a mean birth weight of 800 g at a postnatal age of 1 week, who were suffering from respiratory distress syndrome. The agents were each given in an open, random design. Blood gases were measured and ventilatory efficiency index (VEI) and arterial/alveolar oxygen tension ratio (PaO2/PAO2) were calculated five minutes before and 30 minutes after administration. Heart rate and mean arterial blood pressure were noted. The mean PaO2 improved by 0.61 kPa and 0.69 kPa after salbutamol and ipratropium bromide, respectively and these changes were significantly greater than the 0.5 kPa fall seen with placebo. The mean arterial carbon dioxide tension fell by 0.98 kPa after salbutamol and 0.59 kPa after ipratropium bromide. After both salbutamol and ipratropium bromide, VEI improved significantly (by 23% and 20% respectively) but there was no significant change in the PaO2/PAO2, suggesting that respiratory mechanics and not ventilation/perfusion balance had improved after a single dose of bronchodilator. We conclude that both salbutamol and ipratropium bromide given by MDIS have useful short term effects in ventilator dependent neonates with respiratory distress syndrome. Precise dose regimens and long term effects remain to be worked out.
منابع مشابه
Bronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of end-inspiratory pause.
The delivery of bronchodilators with a metered-dose inhaler (MDI) and a spacer in mechanically ventilated patients has become widespread practice. However, the various ventilator settings that influence the efficacy of MDI are not well established. Application of an end-inspiratory pause (EIP) during drug delivery has been suggested as one of the factors that might increase the effectiveness of...
متن کاملDelivery of therapeutic aerosols to intubated babies.
Delivery of drug aerosols to the lungs of ventilated neonates by metered dose inhaler and spacer (Aerochamber) and ultrasonic nebuliser (Pentasonic) was assessed using sodium cromoglycate. The mean proportion of a known intratracheal dose of sodium cromoglycate excreted in the urine of four intubated infants was 37.5%. After assuming that 38% of the sodium cromoglycate aerosol reaching the neon...
متن کاملBronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of flow pattern.
In mechanically ventilated patients the flow pattern during bronchodilator delivery by metered-dose inhaler (MDI) could be a factor that might influence the effectiveness of this therapy. In order to test this the effect of two different inspiratory flow patterns on the bronchodilation induced by beta2-agonists administered via MDI and spacer in a group of mechanically ventilated patients with ...
متن کاملInhalation therapy with metered-dose inhalers and dry powder inhalers in mechanically ventilated patients.
Pressurized metered-dose inhalers (pMDIs) are commonly employed for administering bronchodilator aerosols to mechanically ventilated patients. Although it is feasible to employ dry powder inhalers in ventilator circuits, the presence of humidity in the ventilator circuit could reduce their efficiency. A complex array of factors influence drug delivery from pMDIs during mechanical ventilation, a...
متن کاملBronchodilator therapy with metered-dose inhaler and spacer versus nebulizer in mechanically ventilated patients: comparison of magnitude and duration of response.
OBJECTIVE Four-hour comparison of the bronchodilator response of albuterol administered via metered-dose inhaler (MDI) with spacer versus small-volume nebulizer (SVN) to mechanically ventilated patients with chronic obstructive pulmonary disease (COPD). DESIGN Prospective randomized clinical trial. SETTING Medical intensive care unit in a university hospital. PATIENTS Thirteen mechanicall...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood. Fetal and neonatal edition
دوره 70 3 شماره
صفحات -
تاریخ انتشار 1994